SMART KEY SYSTEM (for Entry Function) > Entry Answer-back Buzzer does not Sound |
| 1.READ VALUE USING TECHSTREAM (ANSWER-BACK BUZZER FUNCTION) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Wireless Buzzer Resp | Answer-back buzzer operation / ON or OFF | Customization status displayed | - |
| Result | Proceed to |
| Customize setting is ON. | A |
| Customize setting is OFF. | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM |
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the Techstream.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Wireless Buzzer | Wireless door lock buzzer assembly | ON/OFF | - |
|
| ||||
| OK | ||
| ||