AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM > Headlight Beam Level Control Actuator Circuit |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (Ready).
Turn the intelligent tester on.
Enter the following menus: Body / HL Auto Leveling / Active Test.
Check that the leveling motors operate.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Drive The Leveling Motor UP | Leveling motor upward operation | ON/OFF | ON: Moves up OFF: Stops |
| Drive The Leveling Motor DOWN | Leveling motor downward operation | ON/OFF | ON: Moves down OFF: Stops |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (HEADLIGHT LEVELING MOTOR - HEADLIGHT LEVELING ECU ASSEMBLY) |
Disconnect the A34 headlight leveling ECU assembly connector.
Disconnect the LH side or RH side headlight leveling motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A34-18 (LHT) - A57-2 (LH T) | Always | Below 1 Ω |
| A34-11 (LH+) - A57-3 (LHIG) | Always | Below 1 Ω |
| A34-24 (LH-) - A57-1 (LH E) | Always | Below 1 Ω |
| A34-18 (LHT) - Body ground | Always | 10 kΩ or higher |
| A34-11 (LH+) - Body ground | Always | 10 kΩ or higher |
| A34-24 (LH-) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| A34-17 (RHT) - A56-2 (RH T) | Always | Below 1 Ω |
| A34-10 (RH+) - A56-3 (RHIG) | Always | Below 1 Ω |
| A34-23 (RH-) - A56-1 (RH E) | Always | Below 1 Ω |
| A34-17 (RHT) - Body ground | Always | 10 kΩ or higher |
| A34-10 (RH+) - Body ground | Always | 10 kΩ or higher |
| A34-23 (RH-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK HEADLIGHT LEVELING MOTOR |
Replace the headlight leveling motor with a new or a known good one (Click here).
Perform the active test of the leveling motors.
|
| ||||
| OK | ||
| ||