Home › Vehicle Exterior › LIGHTING (EXT) › AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM

AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM > Headlight Beam Level Control Actuator Circuit

for Preparation Click here


DESCRIPTION

The headlight leveling ECU assembly actuates the headlight leveling motors according to vehicle conditions.

WIRING DIAGRAM


E220279E06


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (Ready).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / HL Auto Leveling / Active Test.

  1. Check that the leveling motors operate.

    HL Auto Leveling 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Drive The Leveling Motor UP
    Leveling motor upward operation
    ON/OFF
    ON: Moves up
    OFF: Stops
    Drive The Leveling Motor DOWN
    Leveling motor downward operation
    ON/OFF
    ON: Moves down
    OFF: Stops

    OK:
    Headlight leveling motors operate normally.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK HARNESS AND CONNECTOR (HEADLIGHT LEVELING MOTOR - HEADLIGHT LEVELING ECU ASSEMBLY)
  1. Disconnect the A34 headlight leveling ECU assembly connector.

  1. Disconnect the LH side or RH side headlight leveling motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    LH Side 
    Tester Connection
    Condition
    Specified Condition
    A34-18 (LHT) - A57-2 (LH T)
    Always
    Below 1 Ω
    A34-11 (LH+) - A57-3 (LHIG)
    Always
    Below 1 Ω
    A34-24 (LH-) - A57-1 (LH E)
    Always
    Below 1 Ω
    A34-18 (LHT) - Body ground
    Always
    10 kΩ or higher
    A34-11 (LH+) - Body ground
    Always
    10 kΩ or higher
    A34-24 (LH-) - Body ground
    Always
    10 kΩ or higher
    RH Side 
    Tester Connection
    Condition
    Specified Condition
    A34-17 (RHT) - A56-2 (RH T)
    Always
    Below 1 Ω
    A34-10 (RH+) - A56-3 (RHIG)
    Always
    Below 1 Ω
    A34-23 (RH-) - A56-1 (RH E)
    Always
    Below 1 Ω
    A34-17 (RHT) - Body ground
    Always
    10 kΩ or higher
    A34-10 (RH+) - Body ground
    Always
    10 kΩ or higher
    A34-23 (RH-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HEADLIGHT LEVELING MOTOR
  1. Replace the headlight leveling motor with a new or a known good one (Click here).

  1. Perform the active test of the leveling motors.

    OK:
    Headlight leveling motors operate normally.



NG
REPLACE HEADLIGHT LEVELING ECU ASSEMBLY (Click here)
OK

END (HEADLIGHT LEVELING MOTOR WAS DEFECTIVE)