This DTC is stored when the combination meter assembly (meter circuit plate) detects a fuel sender gauge assembly malfunction via a direct line.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1500 | Fuel Sender Open Detected | When IG voltage is 9.5 V or more and the following condition is detected:
·
Voltage signal from fuel sender gauge assembly is 0.2 V or less 3 times consecutively ·
Voltage signal from fuel sender gauge assembly is 4.7 V or more 3 times consecutively |
·
Harness or connector ·
Fuel suction tube with pump and gauge assembly ·
Fuel sender gauge assembly ·
Combination meter assembly (Meter circuit plate) |
- | - |
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Fuel Input | Fuel input | Min.: 0 L, Max.: 127.5 L | w/ Canister Pump Module:
Fuel receiver gauge indicates F (1/1): 38.3 L Fuel receiver gauge indicates 3/4: 29.8 L Fuel receiver gauge indicates 1/2: 21.3 L Fuel receiver gauge indicates 1/4: 12.8 L Fuel receiver gauge indicates E (R): 4.3 L w/o Canister Pump Module: Fuel receiver gauge indicates F (1/1): 38.3 L Fuel receiver gauge indicates 3/4: 29.9 L Fuel receiver gauge indicates 1/2: 21.4 L Fuel receiver gauge indicates 1/4: 12.8 L Fuel receiver gauge indicates E (R): 4.3 L |
Unit: Liter |
| Tester Display |
|---|
| Fuel Input |
| Result | Proceed to |
|---|---|
| Fuel level data can be displayed on the GTS and DTC B1500 is output. | A |
| Fuel level data cannot be displayed on the GTS. | B |
A
B
| *a | Component with harness connected
(Combination Meter Assembly (Meter Circuit Plate)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-31 (FV) - Body ground | Power switch on (IG) | 4.5 to 5.5 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Combination Meter Assembly (Meter Circuit Plate)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-29 (FR) - F6-30 (FE&B) | Power switch on (IG) | 0.3 to 4.6 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 combination meter assembly (meter circuit plate) connector.
Disconnect the M10 fuel suction tube with pump and gauge assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-29 (FR) - M10-3 (FR) | Always | Below 1 Ω |
| F6-30 (FE&B) - M10-2 (FE) | Always | Below 1 Ω |
| F6-31 (FV) - M10-1 (FV) | Always | Below 1 Ω |
| F6-29 (FR) or M10-3 (FR) - Body ground | Always | 10 kΩ or higher |
| F6-30 (FE&B) or M10-2 (FE) - Body ground | Always | 10 kΩ or higher |
| F6-31 (FV) or M10-1 (FV) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the fuel sender gauge assembly.
w/ Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/ Canister Pump Module)>REMOVAL
w/o Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/o Canister Pump Module)>REMOVAL
Inspect the fuel sender gauge assembly.
w/ Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/ Canister Pump Module)>INSPECTION
w/o Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/o Canister Pump Module)>INSPECTION
Fuel sender gauge assembly is normal.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
w/ Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/ Canister Pump Module)>REMOVAL
w/o Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL SENDER GAUGE ASSEMBLY(w/o Canister Pump Module)>REMOVAL
| *a | Component without harness connected
(Fuel Suction Tube with Pump and Gauge Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-3 - B-1 | Always | Below 1 Ω |
| A-1 - B-3 | Always | Below 1 Ω |
| A-2 - B-2 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
w/ Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL PUMP(w/ Canister Pump Module)>REMOVAL
w/o Canister Pump Module: Click hereEngine / Hybrid System>2ZR-FXE FUEL>FUEL PUMP(w/o Canister Pump Module)>REMOVAL