The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during ultrasonic sensor removal/installation are shown below.
*1: If a front side ultrasonic sensor (LH, RH) is removed and installed or replaced, it is necessary to perform registration.
1.REMOVE FRONT BUMPER ASSEMBLY
89341M
2.REMOVE FRONT SIDE ULTRASONIC SENSOR
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Disconnect the connector.
|
Remove in this Direction |
Disengage the 2 claws and remove the front side ultrasonic sensor as shown in the illustration.
89348J
3.REMOVE ULTRASONIC SENSOR CLIP
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
|
Remove in this Direction |
Disengage the clamp.
Disengage the 4 claws and remove the ultrasonic sensor clip as shown in the illustration.
89341K
4.REMOVE FRONT CORNER ULTRASONIC SENSOR
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Disconnect the connector.
|
Remove in this Direction |
Disengage the 2 claws and remove the front corner ultrasonic sensor as shown in the illustration.
89341L
5.REMOVE FRONT CENTER ULTRASONIC SENSOR
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Disconnect the connector.
|
Remove in this Direction |
Disengage the 2 claws and remove the front center ultrasonic sensor as shown in the illustration.
89347D
6.REMOVE FRONT SIDE ULTRASONIC SENSOR RETAINER
Perform this procedure only when replacement of the front side ultrasonic sensor retainer is necessary.
When removing the front side ultrasonic sensor retainer, heat the front bumper assembly and front side ultrasonic sensor retainer using a heat light.
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Heat the front bumper assembly and front side ultrasonic sensor retainer using a heat light at the specified temperature for 3 to 5 minutes.
| Item | Temperature |
|---|---|
| Front Bumper Assembly | 40 to 60°C (104 to 140°F) |
| Front Side Ultrasonic Sensor Retainer |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Remove the front side ultrasonic sensor retainer.
89347B
7.REMOVE FRONT CORNER ULTRASONIC SENSOR RETAINER
Perform this procedure only when replacement of the front corner ultrasonic sensor retainer is necessary.
When removing the front corner ultrasonic sensor retainer, heat the front bumper assembly and front corner ultrasonic sensor retainer using a heat light.
The illustration is for the LH side. The orientation for the RH side is the opposite of the LH side.
Heat the front bumper assembly and front corner ultrasonic sensor retainer using a heat light at the specified temperature for 3 to 5 minutes.
| Item | Temperature |
|---|---|
| Front Bumper Assembly | 40 to 60°C (104 to 140°F) |
| Front Corner Ultrasonic Sensor Retainer |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Remove the front corner ultrasonic sensor retainer.