Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM
RM3210E _57 Power Source / Network _047550 NETWORKING _0242017 CAN COMMUNICATION SYSTEM J

NETWORKING  CAN COMMUNICATION SYSTEM  Open in Bus 5 Main Bus Line  


DESCRIPTION

There may be an open circuit in one of the CAN main bus lines when the resistance between terminals 15 (CA5H) and 16 (CA5L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.

Symptom Trouble Area
Resistance between terminals 15 (CA5H) and 16 (CA5L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.
·

CAN main bus lines or connector

·

Meter circuit plate

·

Central gateway ECU (network gateway ECU)

·

No. 3 CAN junction connector



This malfunction is not related to the lines of a CAN branch or to ECUs or sensors connected to a CAN branch.

WIRING DIAGRAM

C346830E13
0.323,1.729 1.094,1.927 0.771,0.198 10 false 120 Ω 6.5,1.729 7.031,1.99 0.531,0.26 10 false 120 Ω 0.094,2.604 2.052,3.083 1.958,0.479 10 false Central Gateway ECU (Network Gateway ECU) 2.688,2.469 4.76,2.771 2.073,0.302 10 false No. 3 CAN Junction Connector 5.927,2.469 7.135,2.792 1.208,0.323 10 false Meter Circuit Plate 0.854,1.365 1.469,1.563 0.615,0.198 10 false CA5H 0.885,1.906 1.5,2.104 0.615,0.198 10 false CA5L 1.365,1.365 1.677,1.563 0.313,0.198 10 false 15 1.354,1.885 1.667,2.083 0.313,0.198 10 false 16 2.073,1.354 2.229,1.552 0.156,0.198 10 false 6 2.031,1.885 2.344,2.083 0.313,0.198 10 false 17 4.979,1.354 5.135,1.552 0.156,0.198 10 false 1 4.948,1.885 5.271,2.177 0.323,0.292 10 false 12 5.688,1.354 6,1.552 0.313,0.198 10 false 26 5.688,1.885 6,2.083 0.313,0.198 10 false 27 5.979,1.365 6.594,1.563 0.615,0.198 10 false CANH 5.99,1.896 6.604,2.094 0.615,0.198 10 false CANL 0.135,2.417 0.594,2.615 0.458,0.198 10 false F59 2.385,2.469 2.844,2.667 0.458,0.198 10 false F71 5.667,2.469 5.979,2.667 0.313,0.198 10 false F6

CAUTION / NOTICE / HINT

NOTICE:
·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

DTC check procedure: Turn the power switch on (IG) and wait at least approximately 20 seconds. Turn the blind spot monitor system on using the blind spot monitor main switch (ON/OFF switch), turn the LDA main switch on and wait for approximately 52 seconds or more.

·

After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM



HINT:
·

Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.

·

When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.



PROCEDURE

1.CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 3 CAN JUNCTION CONNECTOR)
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the F71 No. 3 CAN junction connector.


c.
C348627C14
1.438,0.094 1.865,0.354 0.427,0.26 0.688,1.802 0.688,0.552 0.688,0.552 0.948,0.552 true 0.698,2.125 0.698,3.177 0.698,3.177 0.969,3.177 true 1.719,1.833 1.719,0.823 1.719,0.823 2.01,0.823 true 1.719,2.125 1.719,2.854 1.719,2.854 2.063,2.854 true 0.094,0.104 0.406,0.302 0.313,0.198 10 false *a 1.552,0.177 1.865,0.375 0.313,0.198 10 false F71 1,0.5 1.594,0.667 0.594,0.167 10 false CANH*b 1.031,3.115 1.625,3.281 0.594,0.167 10 false CANL*b 2.063,0.76 2.656,0.927 0.594,0.167 10 false CANH*c 2.125,2.792 2.729,2.927 0.604,0.135 10 false CANL*c
*a Front view of wire harness connector
(to No. 3 CAN Junction Connector)
*b to Meter Circuit Plate
*c to Central Gateway ECU (Network Gateway ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Connected to
F71-1 (CANH) - F71-12 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω Meter circuit plate
F71-6 (CANH) - F71-17 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω Central gateway ECU (network gateway ECU)



Result:
Result Proceed to
OK A
NG (Line to central gateway ECU (network gateway ECU)) B
NG (Line to meter circuit plate) C



A

REPLACE NO. 3 CAN JUNCTION CONNECTOR

B

2.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 3 CAN JUNCTION CONNECTOR)

C

3.CHECK FOR OPEN IN CAN MAIN BUS LINES (METER CIRCUIT PLATE - NO. 3 CAN JUNCTION CONNECTOR)
2.CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 3 CAN JUNCTION CONNECTOR)
a.

Reconnect the F71 No. 3 CAN junction connector.


b.

Disconnect the F59 central gateway ECU (network gateway ECU) connector.


c.
C326490C70
1.552,0.156 1.896,0.354 0.344,0.198 1.375,1.208 1.375,1.854 1.375,1.854 1.208,1.854 true 1.51,1.208 1.51,1.854 1.51,1.854 1.708,1.854 true 0.073,0.073 0.385,0.229 0.313,0.156 10 false *a 0.823,1.792 1.26,1.938 0.438,0.146 10 false CA5H 1.625,0.188 2,0.333 0.375,0.146 10 false F59 1.771,1.792 2.208,1.938 0.438,0.146 10 false CA5L
*a Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F59-15 (CA5H) - F59-16 (CA5L) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

REPLACE CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

NG

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 3 CAN JUNCTION CONNECTOR)

3.CHECK FOR OPEN IN CAN MAIN BUS LINES (METER CIRCUIT PLATE - NO. 3 CAN JUNCTION CONNECTOR)
a.

Reconnect the F71 No. 3 CAN junction connector.


b.

Disconnect the F6 meter circuit plate connector.


c.
C349828C03
1.552,0.615 1.938,0.896 0.385,0.281 1.021,2.625 1.156,2.625 1.156,2.625 1.156,2.125 true 1.448,2.625 1.292,2.625 1.292,2.625 1.292,2.125 true 0.135,0.104 0.448,0.302 0.313,0.198 10 false *a 1.531,2.563 2.115,2.865 0.583,0.302 10 false CANL 0.594,2.563 1.177,2.865 0.583,0.302 10 false CANH 1.688,0.688 2.271,0.99 0.583,0.302 10 false F6
*a Front view of wire harness connector
(to Meter Circuit Plate)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F6-26 (CANH) - F6-27 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

NG

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (METER CIRCUIT PLATE - NO. 3 CAN JUNCTION CONNECTOR)