The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1411/11 | Room Temperature Sensor Circuit | Open or short in room temperature sensor circuit | ·
Cooler (room temp. sensor) thermistor ·
Harness or connector between cooler (room temp. sensor) thermistor and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411/11 may be output even though the system is normal.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Tester Display |
|---|
| Room Temperature Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE
C
| *a | Component without harness connected
(Cooler (Room Temp. Sensor) Thermistor) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
| *e | Allowable Range |
Remove the cooler (room temp. sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F57 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F57-14 (TR) - F51-1 | Always | Below 1 Ω |
| F57-1 (SG-1) - F51-2 | Always | Below 1 Ω |
| F57-14 (TR) or F51-1 - Body ground | Always | 10 kΩ or higher |
| F57-1 (SG-1) or F51-2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG