The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1497/97 | BUS IC Communication Malfunction | Error or open in communication line | ·
Air conditioning harness assembly ·
No. 1 air conditioning radiator damper servo sub-assembly ·
No. 2 air conditioning radiator damper servo sub-assembly ·
No. 3 air conditioning radiator damper servo sub-assembly ·
Air conditioning amplifier assembly |
Memorized
(10 sec. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
for Dual Type
for Single Type
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse | Min.: 128
Max.: 383 |
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 164 to 256 pulses |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
*1: for Dual Type
*2: for Single Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
Each damper servo motor operates smoothly.
| Result | Proceed to |
|---|---|
| All of the damper servo motors are malfunctioning | A |
| Any of the damper servo motors is normal | B |
A
B
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
The damper servo motor operates smoothly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.
Disconnect the z1 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-2 (BUS G) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-4 (B BUS) - Body ground | Power switch on (IG) | 11 to 14 V |
Turn the power switch on (IG).
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Connect an oscilloscope to terminals z1-2 (BUS G) and z1-3 (BUS) of the air conditioning amplifier assembly and check the waveform.
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Item | Content |
|---|---|
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Vehicle Condition | Power switch on (IG) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse | Min.: 128
Max.: 383 |
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 164 to 256 pulses |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
*1: for Dual Type
*2: for Single Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
Each damper servo motor operates smoothly.
| Result | Proceed to |
|---|---|
| Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate | A |
| Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate | B |
| Only the No. 3 air conditioning radiator damper servo sub-assembly does not operate | |
| Only the No. 2 air conditioning radiator damper servo sub-assembly operates |
A
B
Disconnect the z1 air conditioning amplifier assembly connector.
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-2 (BUS G) - 3 (GND) | Always | Below 1 Ω |
| z1-3 (BUS) - 1 (+B) | Always | Below 1 Ω |
| z1-4 (B BUS) - 2 (LIN) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse | Min.: 128
Max.: 383 |
Operates between 255 to 347 pulses |
| Air Outlet Servo Pulse (P) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 164 to 256 pulses |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
*1: for Dual Type
*2: for Single Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (P) |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
Each damper servo motor operates smoothly.
| Result | Proceed to |
|---|---|
| All of the damper servo motors are malfunctioning | A |
| Any of the damper servo motors is normal | B |
A
B
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
The damper servo motor operates smoothly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
When inspecting the air conditioning amplifier assembly, do not bring the tester probes too close to each other as a short circuit may occur.
Disconnect the z1 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-2 (BUS G) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-4 (B BUS) - Body ground | Power switch on (IG) | 11 to 14 V |
Turn the power switch on (IG).
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Connect an oscilloscope to terminals z1-2 (BUS G) and z1-3 (BUS) of the air conditioning amplifier assembly and check the waveform.
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Item | Content |
|---|---|
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Vehicle Condition | Power switch on (IG) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix*1 or air mix*2) pulse | Min.: 128
Max.: 383 |
Operates between 255 to 347 pulses |
| Air Outlet Servo Pulse (P) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 164 to 256 pulses |
| A/O Servo Pulse(Rr D) | No. 3 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 250 to 297 pulses |
*1: for Dual Type
*2: for Single Type
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (P) |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
Each damper servo motor operates smoothly.
| Result | Proceed to |
|---|---|
| Only the No. 1 air conditioning radiator damper servo sub-assembly does not operate | A |
| Only the No. 2 air conditioning radiator damper servo sub-assembly does not operate | B |
| Only the No. 3 air conditioning radiator damper servo sub-assembly does not operate | |
| Only the No. 2 air conditioning radiator damper servo sub-assembly operates |
A
B
Disconnect the z1 air conditioning amplifier assembly connector.
Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-2 (BUS G) - 3 (GND) | Always | Below 1 Ω |
| z1-3 (BUS) - 1 (+B) | Always | Below 1 Ω |
| z1-4 (B BUS) - 2 (LIN) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG