MALFUNCTION DESCRIPTION
This DTC is stored if the value of the reactor current sensor does not change. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter | ·
Inverter internal circuit malfunction ·
Malfunction in ECU that controls the inverter ·
Malfunction in the sensors for inverter control (current sensor, voltage sensors (VH, VL), etc.) |
| HV battery system | Open in a frame wire |
For a description of the boost converter.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P0CA300
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | The value of the reactor current sensor does not change.
(1 trip detection logic) |
·
HV battery junction block assembly ·
Inverter with converter assembly ·
Service plug grip ·
Engine room wire No. 2 ·
Hybrid vehicle control ECU ·
PCU FR fuse ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Apply the parking brake and secure the wheels using chocks.
Turn the power switch on (IG) and turn the GTS on.
Apply the parking brake.
With power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY).
Move the shift lever to D.
Depress the brake pedal firmly with your left foot and fully depress the accelerator pedal for 5 seconds, and then release it.
Make sure to fully apply the parking brake and firmly depress the brake pedal to prevent the vehicle from moving.
If the engine starts before depressing the accelerator pedal, select park (P) , wait until the engine stops, and then select drive (D) and repeat this step.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0E512A only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased |
| P1C7D49 | Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased | ||
| P1C7E49 | Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased | ||
| P1C7F49 | Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased | ||
| System Main Relay or High Voltage Circuit Malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| HV Battery Malfunction | Hybrid control system | P0AFC16 | Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |
| P0AFC96 | Hybrid/EV Battery Sensor Module Component Internal Failure | ||
| P1AC000 | Hybrid/EV Battery Cell Low Voltage | ||
| P1AD01B | Hybrid/EV Battery Block Internal Resistance High | ||
| P1CBE1E | Hybrid/EV Battery Block 1 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CBF1E | Hybrid/EV Battery Block 2 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC01E | Hybrid/EV Battery Block 3 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC11E | Hybrid/EV Battery Block 4 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC21E | Hybrid/EV Battery Block 5 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC31E | Hybrid/EV Battery Block 6 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC41E | Hybrid/EV Battery Block 7 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC51E | Hybrid/EV Battery Block 8 (Voltage Difference) Circuit Resistance Out of Range | ||
| P1CC61E | Hybrid/EV Battery Block 9 (Voltage Difference) Circuit Resistance Out of Range | ||
| P301100 | Hybrid/EV Battery Block 1 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301200 | Hybrid/EV Battery Block 2 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301300 | Hybrid/EV Battery Block 3 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301400 | Hybrid/EV Battery Block 4 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301500 | Hybrid/EV Battery Block 5 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301600 | Hybrid/EV Battery Block 6 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301700 | Hybrid/EV Battery Block 7 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301800 | Hybrid/EV Battery Block 8 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| P301900 | Hybrid/EV Battery Block 9 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) | ||
| U029A87 | Lost Communication with Hybrid/EV Battery Sensor Module Missing Message | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module |
| P0A1A49 | Drive Motor "A" Control Module | ||
| P0A1B1F | Drive Motor "B" Control Module | ||
| P1C2A1C | Hybrid Powertrain Control Module | ||
| P1C2A49 | Generator A/D Converter Circuit | ||
| P1C2B1C | Drive Motor "A" A/D Converter Circuit | ||
| P1C2B49 | Drive Motor "B" A/D Converter Circuit | ||
| P313383 | Generator Control Module Malfunction | ||
| P313386 | Drive Motor Control Module Malfunction | ||
| P313387 | Drive Motor "B" Control Module Malfunction | ||
| P313483 | Generator Position Sensor Angle Malfunction | ||
| P313486 | Drive Motor "A" Position Sensor Angle Malfunction | ||
| P313487 | Drive Motor "B" Position Sensor Angle Malfunction | ||
| Hybrid control system | P0A1B49 | Generator Position Sensor REF Signal Cycle Malfunction | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
| Hybrid control system | P312387 | Lost Communication with Missing Message | |
| Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
| P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
| P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
| P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
| P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
| P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
| P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P0D2D1C | Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range | ||
| P0E311C | Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range | ||
| System Malfunction | Motor generator control system | P0A9000 | Drive Motor "A" Performance |
| P0A9200 | Hybrid Generator Performance | ||
| P0BFF1D | Drive Motor "A" Circuit Current Out of Range | ||
| P0C1900 | Drive Motor "A" Execution Torque Performance | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
| P0E7100 | Generator Execution Torque Performance | ||
| P1CA51D | Hybrid Generator Circuit Current Out of Range | ||
| Hybrid control system | P0AA649 | Hybrid/EV Battery Voltage System Insulation Resistance Decreased | |
P0E512A may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT