Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM
RM3210E _51 Engine / Hybrid System _047524 HYBRID / BATTERY CONTROL _0242209 MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P1CAC49  Generator Position Sensor Internal Electronic Failure  P1C641F  Generator Control Module Circuit Intermittent  P1CAF38  Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect  


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and detects malfunctions.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1C641F Generator Control Module Circuit Intermittent Excitation signal (REF signal) for resolver angle detection cycle malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Does not come on Master Warning Light:
Does not come on
P1CAC49 Generator Position Sensor Internal Electronic Failure Generator resolver angle malfunction:
The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit.
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Comes on Master Warning Light:
Comes on
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect Resolver REF signal cycle malfunction:
Excitation signal (REF signal) for resolver angle detection cycle malfunction
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P1CAC49 Generator Revolution
P1CAF28

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.*

*: Lightly wiggle the connectors and wire harnesses up and down and right and left.

7.

Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.

9.

Keep the engine running for 5 seconds or more.

10.

Select drive (D) and drive the vehicle forward for 5 m (16 ft.) or more.

11.

Select reverse (R) and drive the vehicle backward for 5 m (16 ft.) or more.

12.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

13.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A335061E04
0.813,0.542 2.104,0.781 1.292,0.24 10 false Excitation Coil 2.552,0.688 3.01,0.885 0.458,0.198 10 false GRF 5,0.688 5.458,0.885 0.458,0.198 10 false GRF 2.458,1.021 3.073,1.219 0.615,0.198 10 false GRFG 5,1.021 5.615,1.219 0.615,0.198 10 false GRFG 2.542,1.344 3,1.542 0.458,0.198 10 false GSN 5,1.448 5.458,1.646 0.458,0.198 10 false GSN 2.458,1.677 3.073,1.875 0.615,0.198 10 false GSNG 5,1.792 5.615,1.99 0.615,0.198 10 false GSNG 2.563,2 3.021,2.198 0.458,0.198 10 false GCS 5.01,2.115 5.469,2.313 0.458,0.198 10 false GCS 2.458,2.333 3.073,2.531 0.615,0.198 10 false GCSG 5.01,2.448 5.625,2.646 0.615,0.198 10 false GCSG 5.01,2.792 5.625,2.99 0.615,0.198 10 false DRN3 0.656,2.885 3.406,3.083 2.75,0.198 10 false Generator Resolver 0.656,2.719 0.969,2.917 0.313,0.198 10 false C1 5.646,0.781 6.99,1.198 1.344,0.417 10 false Oscillation Circuit 0.458,6.188 2.813,6.5 2.354,0.313 10 false Hybrid Vehicle Transaxle Assembly 0.792,3.469 2.083,3.708 1.292,0.24 10 false Excitation Coil 4.906,6.177 6.979,6.646 2.073,0.469 10 false Inverter with Converter Assembly 4.573,6.177 5.031,6.375 0.458,0.198 10 false C32 3,0.688 3.156,0.885 0.156,0.198 10 false 1 3,1.031 3.156,1.229 0.156,0.198 10 false 8 2.969,1.344 3.188,1.542 0.219,0.198 10 false 12 3,1.677 3.156,1.875 0.156,0.198 10 false 2 3,2 3.156,2.198 0.156,0.198 10 false 7 2.99,2.333 3.219,2.542 0.229,0.208 10 false 11 4.76,0.698 4.917,0.896 0.156,0.198 10 false 8 4.76,1.021 4.917,1.219 0.156,0.198 10 false 9 4.698,1.344 5.01,1.542 0.313,0.198 10 false 10 4.698,1.667 5.01,1.865 0.313,0.198 10 false 11 4.698,2 5.01,2.198 0.313,0.198 10 false 13 4.698,2.323 5.01,2.521 0.313,0.198 10 false 12 4.76,2.677 4.917,2.875 0.156,0.198 10 false 7 0.646,5.76 2.792,5.958 2.146,0.198 10 false Motor Resolver 0.646,5.604 0.958,5.802 0.313,0.198 10 false C1 2.542,3.604 3,3.802 0.458,0.198 10 false MRF 5.01,3.604 5.469,3.802 0.458,0.198 10 false MRF 2.438,3.927 3.052,4.125 0.615,0.198 10 false MRFG 5,3.927 5.615,4.125 0.615,0.198 10 false MRFG 2.542,4.25 3,4.448 0.458,0.198 10 false MSN 5.01,4.365 5.469,4.563 0.458,0.198 10 false MSN 2.438,4.583 3.052,4.781 0.615,0.198 10 false MSNG 5.01,4.688 5.625,4.885 0.615,0.198 10 false MSNG 2.542,4.917 3,5.115 0.458,0.198 10 false MCS 5.01,5.01 5.469,5.208 0.458,0.198 10 false MCS 2.438,5.24 3.052,5.438 0.615,0.198 10 false MCSG 5.01,5.333 5.625,5.531 0.615,0.198 10 false MCSG 3.021,3.604 3.177,3.802 0.156,0.198 10 false 6 3.021,3.927 3.177,4.125 0.156,0.198 10 false 9 3.021,4.25 3.177,4.448 0.156,0.198 10 false 4 3.031,4.573 3.188,4.771 0.156,0.198 10 false 5 3,4.917 3.25,5.135 0.25,0.219 10 false 10 3,5.24 3.25,5.479 0.25,0.24 10 false 14 4.771,3.604 4.927,3.802 0.156,0.198 10 false 5 4.771,3.927 4.927,4.125 0.156,0.198 10 false 6 4.76,4.25 4.917,4.448 0.156,0.198 10 false 1 4.76,4.583 4.917,4.781 0.156,0.198 10 false 2 4.76,4.906 4.917,5.104 0.156,0.198 10 false 4 4.76,5.24 4.917,5.438 0.156,0.198 10 false 3

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


HINT:
·

If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.

·

If the resolver is malfunctioning, the vehicle may not drive smoothly.

·

When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.

·

As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.



PROCEDURE

1.CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P1CAC49, P1CAF38 or P1C641F only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs are also output. B


Relevant DTC
P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0C6413 Generator Position Sensor Circuit "A" Circuit Open
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C6913 Generator Position Sensor Circuit "B" Circuit Open
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold


e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A365594C03
0.219,0.406 0.552,0.646 0.333,0.24 1.448,1.125 0.521,1.115 true 1.448,1.25 0.75,1.667 true 1.583,1.25 1.333,1.865 true 1.677,1.25 1.979,1.875 true 1.833,1.25 2.375,1.5 true 1.719,1.104 2.354,0.854 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 1.813,1.917 2.271,2.115 0.458,0.198 10 false GCSG 0.177,1.042 0.635,1.24 0.458,0.198 10 false GRF 2.427,0.771 2.885,0.969 0.458,0.198 10 false GRFG 0.396,1.615 0.854,1.813 0.458,0.198 10 false GSN 1.135,1.917 1.594,2.115 0.458,0.198 10 false GSNG 2.458,1.438 2.917,1.635 0.458,0.198 10 false GCS 0.271,0.438 0.729,0.635 0.458,0.198 10 false C32
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C32-8 (GRF) - Body ground Power switch on (IG) Below 1 V
C32-9 (GRFG) - Body ground Power switch on (IG) Below 1 V
C32-10 (GSN) - Body ground Power switch on (IG) Below 1 V
C32-11 (GSNG) - Body ground Power switch on (IG) Below 1 V
C32-13 (GCS) - Body ground Power switch on (IG) Below 1 V
C32-12 (GCSG) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Reconnect the C32 inverter with converter assembly connector and wait for 2 minutes or more.


Result:
Proceed to
OK
NG



OK

4.CHECK GENERATOR RESOLVER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK GENERATOR RESOLVER
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.
A365594C03
0.219,0.406 0.552,0.646 0.333,0.24 1.448,1.125 0.521,1.115 true 1.448,1.25 0.75,1.667 true 1.583,1.25 1.333,1.865 true 1.677,1.25 1.979,1.875 true 1.833,1.25 2.375,1.5 true 1.719,1.104 2.354,0.854 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 1.813,1.917 2.271,2.115 0.458,0.198 10 false GCSG 0.177,1.042 0.635,1.24 0.458,0.198 10 false GRF 2.427,0.771 2.885,0.969 0.458,0.198 10 false GRFG 0.396,1.615 0.854,1.813 0.458,0.198 10 false GSN 1.135,1.917 1.594,2.115 0.458,0.198 10 false GSNG 2.458,1.438 2.917,1.635 0.458,0.198 10 false GCS 0.271,0.438 0.729,0.635 0.458,0.198 10 false C32
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C32-8 (GRF) - C32-9 (GRFG) Power switch off 8.9 to 14.8 Ω
C32-10 (GSN) - C32-11 (GSNG) Power switch off 22.6 to 34.5 Ω
C32-13 (GCS) - C32-12 (GCSG) Power switch off 25.5 to 37.4 Ω


HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}

The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C (°F).)


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C32-8 (GRF) or C32-9 (GRFG)) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-10 (GSN) or C32-11 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-13 (GCS) or C32-12 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher



d.

Reconnect the C32 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

NG

8.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)
5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A365594C04
0.219,0.406 0.552,0.646 0.333,0.24 1.417,0.938 0.573,0.917 true 1.448,1.063 0.625,1.354 true 1.573,0.927 1.521,0.302 true 1.729,1.063 2.427,1.323 true 1.823,0.948 2.406,0.958 true 1.698,0.906 2.344,0.365 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 2.313,0.146 2.771,0.344 0.458,0.198 10 false MCSG 0.25,1.271 0.708,1.469 0.458,0.198 10 false MRF 2.5,1.26 2.958,1.458 0.458,0.198 10 false MRFG 0.219,0.802 0.677,1 0.458,0.198 10 false MSN 1.323,0.094 1.781,0.292 0.458,0.198 10 false MSNG 2.521,0.875 2.979,1.073 0.458,0.198 10 false MCS 0.271,0.438 0.729,0.635 0.458,0.198 10 false C32
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C32-5 (MRF) - Body ground Power switch on (IG) Below 1 V
C32-6 (MRFG) - Body ground Power switch on (IG) Below 1 V
C32-1 (MSN) - Body ground Power switch on (IG) Below 1 V
C32-2 (MSNG) - Body ground Power switch on (IG) Below 1 V
C32-4 (MCS) - Body ground Power switch on (IG) Below 1 V
C32-3 (MCSG) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Reconnect the C32 inverter with converter assembly connector and wait for 2 minutes or more.


Result:
Proceed to
OK
NG



OK

6.CHECK MOTOR RESOLVER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK MOTOR RESOLVER
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.
A365594C04
0.219,0.406 0.552,0.646 0.333,0.24 1.417,0.938 0.573,0.917 true 1.448,1.063 0.625,1.354 true 1.573,0.927 1.521,0.302 true 1.729,1.063 2.427,1.323 true 1.823,0.948 2.406,0.958 true 1.698,0.906 2.344,0.365 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 2.313,0.146 2.771,0.344 0.458,0.198 10 false MCSG 0.25,1.271 0.708,1.469 0.458,0.198 10 false MRF 2.5,1.26 2.958,1.458 0.458,0.198 10 false MRFG 0.219,0.802 0.677,1 0.458,0.198 10 false MSN 1.323,0.094 1.781,0.292 0.458,0.198 10 false MSNG 2.521,0.875 2.979,1.073 0.458,0.198 10 false MCS 0.271,0.438 0.729,0.635 0.458,0.198 10 false C32
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C32-5 (MRF) - C32-6 (MRFG) Power switch off 8.9 to 14.9 Ω
C32-1 (MSN) - C32-2 (MSNG) Power switch off 16.2 to 28.1 Ω
C32-4 (MCS) - C32-3 (MCSG) Power switch off 18.2 to 30.1 Ω


HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}

The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C (°F).)


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C32-5 (MRF) or C32-6 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-1 (MSN) or C32-2 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-4 (MCS) or C32-3 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher



d.

Reconnect the C32 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

7.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)

NG

10.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)
7.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)
a.
A376649

Check the connection condition of the resolver connector and the contact pressure of each terminal. Check the terminals for deformation the connector for water and foreign matter.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.



Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)
a.
A376649

Check the connection condition of the resolver connector and the contact pressure of each terminal. Check the terminals for deformation the connector for water and foreign matter.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.



Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.

Disconnect the C1 resolver connector.


d.

Measure the resistance according to the value(s) in the table below.

A377942C02
0.604,1.333 0.958,1.563 0.354,0.229 3.865,1.323 4.219,1.552 0.354,0.229 5.042,1.479 4.302,1.719 true 5.052,1.583 4.438,2.146 true 5.167,1.583 4.875,2.125 true 5.26,1.573 5.583,2.146 true 5.302,1.458 5.927,1.063 true 5.375,1.573 5.927,1.781 true 2.021,1.51 1.292,1.188 true 2.198,1.646 2.104,2.104 true 2.021,1.646 1.385,2.094 true 2.24,1.479 2.875,2.104 true 2.094,1.302 2.281,0.604 true 1.906,1.313 1.479,0.698 true 0.24,0.219 0.552,0.417 0.313,0.198 10 false *a 3.667,0.156 3.979,0.354 0.313,0.198 10 false *b 0.698,1.385 1.01,1.583 0.313,0.198 10 false C1 3.917,1.365 4.229,1.563 0.313,0.198 10 false C32 1.313,0.542 1.771,0.74 0.458,0.198 10 false GRF 2.76,2.156 3.375,2.354 0.615,0.198 10 false GRFG 0.979,1.104 1.438,1.302 0.458,0.198 10 false GCS 1.188,2.156 1.802,2.354 0.615,0.198 10 false GCSG 1.927,2.167 2.385,2.365 0.458,0.198 10 false GSN 2.094,0.427 2.708,0.625 0.615,0.198 10 false GSNG 4.708,2.219 5.323,2.417 0.615,0.198 10 false GSNG 5.51,2.229 6.125,2.427 0.615,0.198 10 false GCSG 5.979,1.719 6.438,1.917 0.458,0.198 10 false GCS 5.99,1 6.604,1.198 0.615,0.198 10 false GRFG 4.115,2.104 4.573,2.302 0.458,0.198 10 false GSN 4.01,1.677 4.469,1.875 0.458,0.198 10 false GRF
*a Front view of wire harness connector
(to Resolver)
*b Front view of wire harness connector
(to Inverter with Converter Assembly)


Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C32-8 (GRF) - C1-1 (GRF) Power switch off Below 1 Ω
C32-9 (GRFG) - C1-8 (GRFG) Power switch off Below 1 Ω
C32-10 (GSN) - C1-12 (GSN) Power switch off Below 1 Ω
C32-11 (GSNG) - C1-2 (GSNG) Power switch off Below 1 Ω
C32-13 (GCS) - C1-7 (GCS) Power switch off Below 1 Ω
C32-12 (GCSG) - C1-11 (GCSG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C32-8 (GRF) or C1-1 (GRF) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-9 (GRFG) or C1-8 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-10 (GSN) or C1-12 (GSN) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-11 (GSNG) or C1-2 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-13 (GCS) or C1-7 (GCS) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-12 (GCSG) or C1-11 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher



e.

Reconnect the C1 resolver connector.


f.

Reconnect the C32 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK CONNECTOR CONNECTION CONDITION (RESOLVER CONNECTOR)
a.
A376649

Check the connection condition of the resolver connector and the contact pressure of each terminal. Check the terminals for deformation the connector for water and foreign matter.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.



Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the C32 inverter with converter assembly connector.


c.

Disconnect the C1 resolver connector.


d.

Measure the resistance according to the value(s) in the table below.

A377942C01
0.604,1.333 0.958,1.563 0.354,0.229 3.865,1.323 4.219,1.552 0.354,0.229 5.052,1.302 4.354,0.833 true 5.052,1.406 4.365,1.844 true 5.156,1.302 4.906,0.573 true 5.25,1.292 5.792,0.531 true 5.365,1.313 5.927,1.073 true 5.25,1.417 5.927,1.781 true 2.26,1.5 1.521,2.094 true 2.417,1.646 2.771,2.104 true 2.458,1.49 2.969,1.74 true 2.563,1.333 2.896,0.76 true 2.406,1.323 2.281,0.604 true 2.26,1.333 1.479,0.698 true 0.24,0.219 0.552,0.417 0.313,0.198 10 false *a 3.667,0.156 3.979,0.354 0.313,0.198 10 false *b 0.698,1.385 1.01,1.583 0.313,0.198 10 false C1 3.917,1.365 4.229,1.563 0.313,0.198 10 false C32 2.792,0.583 3.25,0.781 0.458,0.198 10 false MRF 1.323,2.156 1.938,2.354 0.615,0.198 10 false MRFG 3.042,1.688 3.5,1.885 0.458,0.198 10 false MCS 2.667,2.167 3.281,2.365 0.615,0.198 10 false MCSG 1.333,0.521 1.792,0.719 0.458,0.198 10 false MSN 2.094,0.427 2.708,0.625 0.615,0.198 10 false MSNG 4.656,0.385 5.271,0.583 0.615,0.198 10 false MSNG 5.667,0.354 6.281,0.552 0.615,0.198 10 false MCSG 6,0.99 6.458,1.188 0.458,0.198 10 false MCS 6.01,1.719 6.625,1.917 0.615,0.198 10 false MRFG 4.031,0.75 4.49,0.948 0.458,0.198 10 false MSN 4.052,1.813 4.51,2.01 0.458,0.198 10 false MRF
*a Front view of wire harness connector
(to Resolver)
*b Front view of wire harness connector
(to Inverter with Converter Assembly)


Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C32-5 (MRF) - C1-6 (MRF) Power switch off Below 1 Ω
C32-6 (MRFG) - C1-9 (MRFG) Power switch off Below 1 Ω
C32-1 (MSN) - C1-4 (MSN) Power switch off Below 1 Ω
C32-2 (MSNG) - C1-5 (MSNG) Power switch off Below 1 Ω
C32-4 (MCS) - C1-10 (MCS) Power switch off Below 1 Ω
C32-3 (MCSG) - C1-14 (MCSG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C32-5 (MRF) or C1-6 (MRF) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-6 (MRFG) or C1-9 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-1 (MSN) or C1-4 (MSN) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-2 (MSNG) or C1-5 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-4 (MCS) or C1-10 (MCS) - Body ground and other terminals Power switch off 1 MΩ or higher
C32-3 (MCSG) or C1-14 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher



e.

Reconnect the C1 resolver connector.


f.

Reconnect the C32 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR