The stereo component amplifier assembly receives a vehicle speed signal from the meter circuit plate to control the ASL function.
A voltage of 12 V or 5 V is output from each ECU and then input to the meter circuit plate. The signal is changed to a pulse signal at the transistor in the meter circuit plate. Each ECU controls its respective systems based on this pulse signal.
If a short occurs in any of the ECUs or in the wire harness connected to an ECU, all systems in the following diagram will not operate normally.
Check the output waveform.
Remove the meter circuit plate with the connector(s) still connected.
| *a | Component with harness connected
(Meter Circuit Plate) |
Connect an oscilloscope to terminal F6-19 (+S) and body ground.
Turn the power switch on (IG).
Turn a wheel slowly.
Check the signal waveform according to the condition(s) in the table below.
| Item | Condition |
|---|---|
| Measurement terminal | F6-19 (+S) - Body ground |
| Tool setting | 5 V/DIV., 20 ms./DIV. |
| Vehicle condition | Wheel being rotated |
The waveform is similar to that shown in the illustration.
When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the input waveform.
Remove the stereo component amplifier assembly with the connector(s) still connected.
| *a | Component with harness connected
(Stereo Component Amplifier Assembly) |
Connect an oscilloscope to terminal F61-11 (SPD) and body ground.
Turn the power switch on (IG).
Turn a wheel slowly.
Check the signal waveform according to the condition(s) in the table below.
| Item | Condition |
|---|---|
| Measurement terminal | F61-11 (SPD) - Body ground |
| Tool setting | 5 V/DIV., 20 ms./DIV. |
| Vehicle condition | Wheel being rotated |
The waveform is similar to that shown in the illustration.
When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Disconnect the F61 stereo component amplifier assembly connector.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F61-11 (SPD) - F79-9 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-19 (+S) - F79-7 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F61 stereo component amplifier assembly connector.
Disconnect the F85 No. 17 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F61-11 (SPD) - F85-17 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Disconnect the F85 No. 17 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-19 (+S) - F85-16 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG