This DTC is stored if internal or external brake fluid leaks are detected due to improper sealing in the brake actuator (brake booster with master cylinder assembly) or brake booster pump assembly. Internal leaks are suspected if the pump motor operates frequently without braking.
| DTC No. | Detection Item | INF Code | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|---|
| C1391 | Abnormal Leak in Accumulator | 351 | Either of the following is detected:
1.
When the brake pedal is not depressed and the pump motor is operating, the accumulator pressure sensor value does not increase a certain number of times. 2.
When the brake pedal is not depressed and the pump motor is not operating, the accumulator pressure sensor decrease rate exceeds a certain threshold a certain number of times. |
·
Brake fluid leaks ·
Brake actuator (brake booster with master cylinder assembly) (Malfunctioning internal seal etc.) ·
Brake booster pump assembly (Accumulator internal gas pressure decrease, etc.) |
Electronically controlled brake system DTC |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Brake pedal not depressed and pump motor operating. | ○ | - |
| Brake pedal not depressed and pump motor not operating. | - | ○ | |
| Malfunction Status | The accumulator pressure sensor value does not increase a certain number of times. | ○ | - |
| The accumulator pressure sensor decrease rate exceeds a certain threshold a certain number of times. | - | ○ | |
| Detection Time | - | - | |
| Number of Trips | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
After replacing the brake actuator (brake booster with master cylinder assembly), perform linear solenoid valve offset learning, ABS holding solenoid valve learning, yaw rate and acceleration sensor zero point calibration and system information memorization after performing "Reset Memory".
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>INITIALIZATION
Select the Active Test on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| ECB Solenoid (SLR) Valve Close | Linear solenoid reduction valve (SLR) | Valve close ON/OFF | ECB: Electronically Controlled Brake System |
| Tester Display |
|---|
| ECB Solenoid (SLR) Valve Close |
Select the Data List on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Servo Pressure | Pressure value of servo | Min.: 0.00 MPa, Max.: 24.48 MPa | Brake pedal released: 0.00 to 2.10 MPa | Brake pedal is being depressed: Changes in proportion to the depression force of the brake pedal |
| Tester Display |
|---|
| Servo Pressure |
Perform the Active Test and operate the linear solenoid (SLR) in the brake actuator (brake booster with master cylinder assembly).
Check that the servo pressure output value does not increase when performing the Active Test.
The servo pressure output value does not increase when performing the Active Test.
If the servo pressure output value increases, an internal brake fluid leak in the brake actuator (brake booster with master cylinder assembly) is suspected.
| Result | Proceed to |
|---|---|
| The servo pressure output value increases. | A |
| The servo pressure output value does not increase. | B |
A
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for RHD)>REMOVAL
B
Turn the power switch on (READY).
Select the Data List on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| MT Voltage Value | MT voltage value | Min.: 0.00 V, Max.: 20.00 V | Pump motor off: 0.00 V
Pump motor on: 12.00 V |
- |
| Tester Display |
|---|
| MT Voltage Value |
With the power switch on (READY), check the operation of the pump motor.
The pump motor operates once or more within 20 seconds or operates for 10 seconds or more each time.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for RHD)>REMOVAL
Check for brake fluid leaks in the line from the brake booster pump assembly to the brake booster with master cylinder assembly.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>C1202
There are no brake fluid leaks.
| Proceed to |
|---|
| OK |
| NG |
OK
for the brake booster with master cylinder assembly (for LHD): Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for LHD)>REMOVAL
for the brake booster with master cylinder assembly (for RHD): Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER(for RHD)>REMOVAL
for the brake booster pump assembly (for LHD): Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER PUMP(for LHD)>REMOVAL
for the brake booster pump assembly (for RHD): Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER PUMP(for RHD)>REMOVAL
NG