Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM
RM3210E _59 Vehicle Exterior _047533 LIGHTING (EXT) _0244228 LIGHTING SYSTEM J

LIGHTING (EXT)  LIGHTING SYSTEM  Back-up Light Circuit  


DESCRIPTION

The hybrid vehicle control ECU controls the back-up lights via the BKUP LP relay.

WIRING DIAGRAM

E344254E01
5.823,3.104 6.802,3.5 0.979,0.396 10 false Hybrid Vehicle Control ECU 5.823,2.938 6.188,3.135 0.365,0.198 10 false A50 3.052,3.354 5.427,3.573 2.375,0.219 10 false Rear Combination Light Assembly RH 3.052,3.188 3.417,3.385 0.365,0.198 10 false M42 3.031,2.219 5.406,2.438 2.375,0.219 10 false Rear Combination Light Assembly LH 3.031,2.063 3.396,2.26 0.365,0.198 10 false M43 0.156,2.885 2.813,3.115 2.656,0.229 10 false Instrument Panel Junction Block Assembly 2.417,0.708 2.667,0.906 0.25,0.198 10 false 3F 2.406,1.177 2.771,1.375 0.365,0.198 10 false 3H 0.604,0.708 0.969,0.906 0.365,0.198 10 false 3D 0.781,1.323 1.469,1.531 0.688,0.208 10 false BKUP LP 1.531,1.396 2.292,1.615 0.76,0.219 10 false BKUP LP 2.406,0.51 2.656,0.708 0.25,0.198 10 false 19 2.406,0.969 2.771,1.167 0.365,0.198 10 false 10 0.646,0.521 0.927,0.708 0.281,0.188 10 false 3 3.75,1.865 4.656,2.073 0.906,0.208 10 false Back-up Light 3.719,3.031 4.625,3.24 0.906,0.208 10 false Back-up Light 4.792,1.573 4.948,1.771 0.156,0.198 10 false 4 4.781,2.719 4.938,2.917 0.156,0.198 10 false 4 3.417,2.719 3.573,2.917 0.156,0.198 10 false 2 3.604,2.729 3.76,2.927 0.156,0.198 10 false E 4.573,2.719 4.729,2.917 0.156,0.198 10 false B 4.594,1.583 4.75,1.781 0.156,0.198 10 false B 3.615,1.573 3.771,1.771 0.156,0.198 10 false E 3.438,1.573 3.594,1.771 0.156,0.198 10 false 2 5.917,0.708 6.167,0.906 0.25,0.198 10 false BL 5.667,0.604 5.917,0.802 0.25,0.198 10 false 20 1.51,1.927 2.458,2.313 0.948,0.385 10 false from IG1-NO. 1 Relay

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

·

Before replacing the hybrid vehicle control ECU, refer to Service Bulletin.



PROCEDURE

1.CHECK FOR DTC (HYBRID CONTROL SYSTEM)
a.

Clear the DTCs.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR

Powertrain > Hybrid Control > Clear DTCs
50002 397

b.

Check for DTCs.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR

Powertrain > Hybrid Control > Trouble Codes
50001 397

Result:
Result Proceed to
Hybrid control system DTCs are not output A
Hybrid control system DTCs are output B



A

2.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)

B

2.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
a.

Disconnect the 3D instrument panel junction block assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3D-3 - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - HYBRID VEHICLE CONTROL ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - HYBRID VEHICLE CONTROL ECU)
a.

Disconnect the 3F instrument panel junction block assembly connector.


b.

Disconnect the A50 hybrid vehicle control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3F-19 - A50-20 (BL) Always Below 1 Ω
3F-19 or A50-20 (BL) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

4.CHECK HYBRID VEHICLE CONTROL ECU (OUTPUT VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HYBRID VEHICLE CONTROL ECU (OUTPUT VOLTAGE)
a.

Reconnect the A50 hybrid vehicle control ECU connector.


b.

Reconnect the 3F instrument panel junction block assembly connector.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
3F-19 - Body ground Power switch on (IG), reverse (R) not selected Below 1 V
3F-19 - Body ground Power switch on (IG), reverse (R) selected 11 to 14 V



Result:
Proceed to
OK
NG



OK

5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (OUTPUT VOLTAGE)

NG

5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (OUTPUT VOLTAGE)
a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
3H-10 - Body ground Power switch on (IG), reverse (R) not selected Below 1 V
3H-10 - Body ground Power switch on (IG), reverse (R) selected 11 to 14 V



Result:
Proceed to
OK
NG



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY