These DTCs are stored when communication between the radio and display receiver assembly and combination meter assembly or headup display (meter mirror sub-assembly) is not possible.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| B1324 | Lost Communication with Meter | After the radio and display receiver assembly receives a registration information signal, which is sent by the combination meter assembly when the power switch is on (ACC), 1 or more times, the radio and display receiver assembly does not receive the signal for 30 seconds or more. | ·
Local bus communication line ·
Combination meter assembly power source circuit ·
Combination meter assembly ·
Radio and display receiver assembly ·
Harness or connector |
| B1325 | Lost Communication with HUD | After the radio and display receiver assembly receives a registration information signal, which is sent by the headup display (meter mirror sub-assembly) when the power switch is on (ACC), 1 or more times, the radio and display receiver assembly does not receive the signal for 30 seconds or more* | ·
Local bus communication line ·
Headup display (meter mirror sub-assembly) power source circuit ·
Headup display (meter mirror sub-assembly)* ·
Radio and display receiver assembly ·
Harness or connector |
*: w/ Headup Display System
The radio and display receiver assembly is the master unit.
Inspect the fuses for circuits related to this system before performing the following procedure.
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Clear the DTCs.
Recheck for DTCs and check that no DTCs are output.
| Result | Proceed to |
|---|---|
| DTC B1324 and B1325 are not output | A |
| DTC B1324 and B1325 are output
(w/ Headup Display System) |
B |
| DTC B1324 is output | C |
| DTC B1325 is output
(w/ Headup Display System) |
D |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
D
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-2 - F79-13 | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Below 54 Ω) | B |
| NG (70 Ω or higher) | C |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-2 - F79-13 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-1 - F79-12 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Disconnect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-3 - F79-14 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-3 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-14 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-3 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| F79-14 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the G7 combination meter mirror ECU connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-7 (LCL+) - G7-8 (LCL-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F6 meter circuit plate connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-33 (MSCH) - F6-34 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Connect the F34 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-2 - F79-13 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-28 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-22 (B) - Body ground | Power switch off | 11 to 14 V |
| F6-21 (IG+) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Connect the F6 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-1 - F79-12 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-2 - F79-13 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F6 meter circuit plate connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-33 (MSCH) - F6-34 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-6 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-1 (B) - Body ground | Power switch off | 11 to 14 V |
| G7-2 (IG) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Connect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-3 - F79-14 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-3 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-14 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F79-3 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| F79-14 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F79-2 - F79-13 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the G7 combination meter mirror ECU connector.
Connect the F79 No. 11 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-7 (LCL+) - G7-8 (LCL-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear the DTCs.
Recheck for DTCs and check that no DTCs are output.
| Result | Proceed to |
|---|---|
| DTC B1324 and B1325 are not output | A |
| DTC B1324 and B1325 are output
(w/ Headup Display System) |
B |
| DTC B1324 is output | C |
| DTC B1325 is output
(w/ Headup Display System) |
D |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
D
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-5 - F77-16 | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Below 54 Ω) | B |
| NG (70 Ω or higher) | C |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-5 - F77-16 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-7 - F77-18 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Disconnect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-6 - F77-17 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-6 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-17 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-6 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| F77-17 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the G7 combination meter mirror ECU connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-7 (LCL+) - G7-8 (LCL-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F6 meter circuit plate connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-33 (MSCH) - F6-34 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Connect the F34 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-5 - F77-16 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-28 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-22 (B) - Body ground | Power switch off | 11 to 14 V |
| F6-21 (IG+) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Connect the F6 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-7 - F77-18 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-5 - F77-16 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F6 meter circuit plate connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-33 (MSCH) - F6-34 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-6 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-1 (B) - Body ground | Power switch off | 11 to 14 V |
| G7-2 (IG) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Connect the G7 combination meter mirror ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-6 - F77-17 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-6 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-17 - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| F77-6 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| F77-17 - G7-1 (B) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-5 - F77-16 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the F34 radio and display receiver assembly connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F34-3 (CNH1) - F34-4 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the G7 combination meter mirror ECU connector.
Connect the F77 No. 9 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G7-7 (LCL+) - G7-8 (LCL-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG