Yaw Rate Sensor Communication Stop Mode
Circuit diagnosis · Vehicles built from Aug 2008
Versions by build date: Nov 2005 – Jul 2008 from Aug 2008
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| Yaw Rate Sensor Communication Stop Mode |
|
|
- HINT:
- For vehicle with Vehicle Stability Control System only.
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistances of the main wire and the branch wire.
- For Auto:
After the ignition switch is turned off, check that the key reminder warning system is not in operation.
- For Reminder:
After the ignition switch is turned off, check that the key reminder warning system and light reminder buzzer are not in operation.
- Before measuring the resistance, leave the vehicle for at least 1 minute and do not operate the ignition switch, any switches or doors. If doors need to be opened in order to check connectors, open the doors and leave them open.
- Turn the ignition switch off before measuring the resistances of the main wire and the branch wire.
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistance of the main wire and the branch wire.
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
| NEXT | |
| 2. CHECK FOR OPEN IN CAN BUS WIRE (YAW RATE SENSOR BRANCH WIRE) |
![]() ![]() |
Disconnect the K25 yaw rate sensor connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
K25-3 (CANH) - K25-2 (CANL)
Ignition switch off
54 to 69 Ω
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (YAW RATE SENSOR - BATTERY AND BODY GROUND) |
Connect the cable to the negative (-) battery terminal.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Disconnect the K25 yaw rate sensor connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
K25-1 (GND) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
K25-4 (IG) - Body ground
Ignition switch on (IG)
11 to 14 V
|
|
||||
| OK | ||
| ||