ECM Communication Stop Mode
Circuit diagnosis · Vehicles built from Nov 2005
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| ECM COMMUNICATION STOP MODE |
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistances of the main wire and the branch wire.
- For Auto:
After the ignition switch is turned off, check that the key reminder warning system is not in operation.
- For Reminder:
After the ignition switch is turned off, check that the key reminder warning system and light reminder buzzer are not in operation.
- Before measuring the resistance, leave the vehicle for at least 1 minute and do not operate the ignition switch, any switches or doors. If doors need to be opened in order to check connectors, open the doors and leave them open.
- Turn the ignition switch off before measuring the resistances of the main wire and the branch wire.
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. CHECK WIRE HARNESS (ECM - BATTERY AND BODY GROUND) |
Disconnect the A12 and B32 ECM connectors.


Measure the resistance of the wire harness side connector.
- Standard resistance:
- for Gasoline Engine:
Tester Connection
Specified Condition
B32-104 (E1) - Body ground
Below 1 Ω
B32-45 (E01) - Body ground
Below 1 Ω
B32-44 (E02) - Body ground
Below 1 Ω
B32-86 (E03) - Body ground
Below 1 Ω
B32-46 (E04) - Body ground
Below 1 Ω
B32-43 (ME01) - Body ground
Below 1 Ω
- for Diesel Engine:
Tester Connection
Specified Condition
B32-109 (E1) - Body ground
Below 1 Ω
B32-45 (E01) - Body ground
Below 1 Ω
B32-44 (E02) - Body ground
Below 1 Ω
B32-46 (E05) - Body ground
Below 1 Ω
Measure the voltage of the wire harness side connector.
- Standard voltage:
- for Gasoline Engine:
Tester Connection
Condition
Specified Condition
A12-1 (+B2) - Body ground
When battery's positive (+) voltage is applied to terminal MREL
10 to 14 V
A12-2 (+B) - Body ground
When battery's positive (+) voltage is applied to terminal MREL
10 to 14 V
A12-3 (+BM) - Body ground
Always
10 to 14 V
A12-20 (BATT) - Body ground
Always
10 to 14 V
A12-28 (IGSW) - Body ground
Ignition switch on (IG)
10 to 14 V
- for Diesel Engine:
Tester Connection
Condition
Specified Condition
A12-2 (BATT) - Body ground
Always
10 to 14 V
A12-1 (+B) - Body ground
When battery's positive (+) voltage is applied to terminal MREL
10 to 14 V
A12-25 (IGSW) - Body ground
Ignition switch on (IG)
10 to 14 V
|
|
||||
| OK | ||
| ||