Entire Combination Meter does not Operate
Circuit diagnosis · Vehicles built from Nov 2005
DESCRIPTION
This circuit provides power to the combination meter assembly.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT FUSE (GAUGE2, ECU-B, IG2) |
Remove the GAUGE2 fuse from the instrument panel junction block.
Remove the ECU-B fuse from the No. 2 relay block.
Remove the IG2 fuse from the No. 1 relay block.
Measure the resistance of the fuses.
- Standard resistance:
- Below 1 Ω
|
|
||||
| OK | |
| 2. INSPECT IG2 RELAY |
Remove the IG2 relay from the No. 1 relay block.

Measure the resistance of the relay.
- Standard resistance:
Tester Connection
Specified Condition
3 - 5
10 kΩ or higher
3 - 5
Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND) |
Disconnect the E22 meter connector.

Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E22-22 (B) - Body ground
Always
10 to 14 V
E22-21 (IG+) - Body ground
Ignition switch on (IG)
10 to 14 V
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E22-33 (ET) - Body ground
Below 1 Ω
|
|
||||
| OK | ||
| ||