P0660 Intake Manifold Tuning Valve Control Circuit / Open (Bank 1)
Diagnostic trouble codes · Vehicles built from Aug 2007
DESCRIPTION
This circuit opens and closes the Intake Air Control Valve (IACV) in response to changes in the engine load in order to increase the intake efficiency (ACIS: Acoustic Control Induction System).When the engine speed is between 0 and 4450 rpm and the throttle valve opening angle is 60° or more, the ECM supplies current to the VSV (ON status), to close the IACV. Under other conditions, the VSV is usually OFF and the IACV is open.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0660 |
The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.
Check if operating noise can be heard when operating the air intake control valve using the intelligent tester.
- OK:
- Operating noise can be heard.
|
|
||||
| NG | |
| 2. CHECK INTAKE AIR CONTROL VALVE (ACIS OPERATION) |
Disconnect the ACIS actuator connector.

Apply battery voltage between the terminals of the ACIS actuator connector.
Check intake air control valve operation.
- OK:
- Operating noise can be heard.
|
|
||||
| OK | |
| 3. INSPECT ACIS ACTUATOR (POWER SOURCE) |
Disconnect the ACIS actuator connector.

Turn the ignition switch to the ON position.
Measure the voltage between the terminals of the AICS actuator connector.
- Standard voltage:
Tester Connection
Specified Condition
1 - 2
9 to 14 V
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR |
Disconnect the ACIS actuator connector.

Disconnect the ECM connector.
Measure the resistance between the terminals of the ACIS connector and ECM connector.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
ACIS actuator (B92-1) - ACIS (B96-107)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
ACIS actuator (B92-1) or ACIS (B96-107) - Body ground
10 kΩ or higher
Reconnect the ECM connector.
Reconnect the ACIS connector.
|
|
||||
| OK | ||
| ||