ECD SYSTEM (for DPF) > Pre-heating Control Circuit |



| 1.CHECK TERMINAL VOLTAGE (GLOW PLUG RELAY) |
![]() |
Remove the glow plug relay.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B43-4 - Body ground | Ignition switch ON | 11 to 14 V |
| *1 | Front view of wire harness connector (to Glow Plug Relay) |
Reinstall the glow plug relay.
|
| ||||
| OK | |
| 2.INSPECT GLOW PLUG RELAY |
![]() |
Remove the glow plug relay.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 4 | When battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | When battery voltage is not applied to terminals 1 and 2 | Below 1 Ω |
Reinstall the glow plug relay.
|
| ||||
| OK | |
| 3.INSPECT GLOW PLUG ASSEMBLY (RESISTANCE) |
![]() |
Disconnect the glow plug wire.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Glow plug terminal - Body ground | 20°C (68°F) | Approximately 1.0 Ω |
Reconnect the glow plug wire.
|
| ||||
| OK | |
| 4.CHECK GLOW PLUG ASSEMBLY (INSTALLATION) |
Check the glow plug installation.
|
| ||||
| OK | |
| 5.CHECK WIRE HARNESS (GLOW PLUG - GLOW PLUG RELAY - BODY GROUND) |
![]() |
Remove the glow plug relay.
Disconnect the glow plug connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B43-3 - B49-1 | Always | Below 1 Ω |
| B43-1 - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B43-3 or B49-1 - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Glow Plug Relay) |
| *2 | Front view of wire harness connector (to Glow Plug) |
Reinstall the glow plug relay.
Reconnect the glow plug connector.
|
| ||||
| OK | |
| 6.CHECK WIRE HARNESS (GLOW PLUG RELAY - ECM AND BODY GROUND) |
![]() |
Remove the glow plug relay.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B43-2 - B32-58 (GREL) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B43-2 or B32-58 (GREL) - Body ground | Always | 10 kΩ or higher |
| *1 | Front view of wire harness connector (to Glow Plug Relay) |
| *2 | Front view of wire harness connector (to ECM) |
Reinstall the glow plug relay.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||