C1241
| Any of the following is detected:
- At a vehicle speed of 3 km/h (2 mph) or more, the IG1 terminal voltage is less than 9.5 V for 10 seconds or more.
- When the solenoid relay remains on and the IG1 terminal voltage is less than 9.5 V, the relay contact is open for 0.22 seconds or more.
- With the IG1 terminal voltage 9.5 V or less, the vehicle speed sensor power supply decreases for 60 seconds or more.
- When the motor fail-safe relay is on after the motor relay turns on, the IG1 terminal voltage is 9.5 V or less and the actuator pump drive motor is off for 0.22 seconds or more.
| - ECU-IG1 fuse
- Battery
- Charging system
- Power source circuit
- Internal power supply circuit of the skid control ECU
|