Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › CONDENSER

CONDENSER > INSTALLATION

for Preparation Click here



1. INSTALL COOLER DRYER


    E050386E01
  1. Using pliers, install the cooler dryer.



    E055408E01
  1. Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the cap.



    I030086E01
  1. Using a 14 mm socket hexagon wrench, install the cap to the modulator.

    Torque:
    2.9 N*m{ 29 kgf*cm , 25 in.*lbf }



2. INSTALL COOLER CONDENSER ASSEMBLY


    E126558
  1. Install the cooler condenser.



3. INSTALL NO. 2 FAN SHROUD


E126556
  1. Install the fan shroud with the 2 bolts.

    Torque:
    10.5 N*m{ 107 kgf*cm , 8 ft.*lbf }



4. INSTALL UPPER RADIATOR SUPPORT


E126555
  1. Install the 2 brackets with the 2 bolts.

    Torque:
    19 N*m{ 194 kgf*cm , 14 ft.*lbf }



5. INSTALL LIQUID PIPE SUB-ASSEMBLY


H102043
  1. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the liquid pipe sub-assembly.

  1. Install the liquid pipe sub-assembly on the cooler condenser with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 7 ft.*lbf }



6. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE


H102042
  1. Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring on the cooler refrigerant discharge hose.

  1. Install the cooler refrigerant discharge hose on the cooler condenser with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 7 ft.*lbf }



7. ADJUST HOOD SUB-ASSEMBLY


B127320E01
  1. Install the hood with the 4 bolts.

    Torque:
    13 N*m{ 133 kgf*cm , 10 ft.*lbf }

  1. Adjust the hood position (Click here).



8. INSTALL FRONT BUMPER COVER
  1. w/ Under Guard:
    Install the front bumper cover (Click here).

  1. w/o Under Guard:
    Install the front bumper cover (Click here).

  1. w/ Hood Moulding:
    Install the front bumper cover (Click here).



9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


10. CHARGE REFRIGERANT
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    430 +-30 g (15.2 +-1.1 oz.)

    SST
    09985-20010   (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)


    I037365E02

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by measuring its quantity, and not with the sight glass.



11. WARM UP ENGINE
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    430 +-30 g (15.2 +-1.1 oz.)

    SST
    09985-20010   (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)


    I037365E02

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by measuring its quantity, and not with the sight glass.



12. CHECK FOR LEAKAGE OF REFRIGERANT
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation under these conditions:

    1. Stop the engine.
    2. Secure good ventilation (the gas leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that some refrigerant remains in the refrigeration system. When compressor is off: approximately 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)



    I042222E12
  1. Using a gas leak detector, check the refrigerant line for leakage.

  1. If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.

  1. Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.