CONDENSER > INSTALLATION |
| 1. INSTALL COOLER DRYER |
![]() |
Using pliers, install the cooler dryer.
![]() |
Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.
Install the O-ring to the cap.
![]() |
Using a 14 mm socket hexagon wrench, install the cap to the modulator.
| 2. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser.
| 3. INSTALL NO. 2 FAN SHROUD |
![]() |
Install the fan shroud with the 2 bolts.
| 4. INSTALL UPPER RADIATOR SUPPORT |
![]() |
Install the 2 brackets with the 2 bolts.
| 5. INSTALL LIQUID PIPE SUB-ASSEMBLY |
![]() |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on the liquid pipe sub-assembly.
Install the liquid pipe sub-assembly on the cooler condenser with the bolt.
| 6. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring on the cooler refrigerant discharge hose.
Install the cooler refrigerant discharge hose on the cooler condenser with the bolt.
| 7. ADJUST HOOD SUB-ASSEMBLY |
![]() |
Install the hood with the 4 bolts.
Adjust the hood position (Click here).
| 8. INSTALL FRONT BUMPER COVER |
w/ Under Guard:
Install the front bumper cover (Click here).
w/o Under Guard:
Install the front bumper cover (Click here).
w/ Hood Moulding:
Install the front bumper cover (Click here).
| 9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 10. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 11. WARM UP ENGINE |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 12. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a gas leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.