C1241/41
| When one of following conditions is met:
- At vehicle speed of 3 km/h (2 mph) or more, IG1 terminal voltage is 9.5 V or less for 10 seconds or more.
- When solenoid relay remains ON and IG1 terminal voltage is 9.5 V or less, relay contact open for 0.2 seconds or more.
- When motor relay remains ON and IG1 terminal voltage becomes 9.5 V or less, actuator pump motor is OFF for 0.1 seconds or more.
- When IG1 terminal voltage is 9.5 V or less, vehicle speed sensor power supply decreases for 60 seconds or more.
| - Battery
- Charging system
- Power source circuit
- Internal power supply circuit of skid control ECU
|