When the blind spot monitor main switch (warning cancel switch assembly) is turned on, a signal is sent to the blind spot monitor sensor LH and the blind spot monitor indicator on the blind spot monitor main switch (warning cancel switch assembly) illuminates. The blind spot monitor system operates according to this signal.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check that the blind spot monitor indicator on the blind spot monitor main switch (warning cancel switch assembly) illuminates normally when the blind spot monitor main switch (warning cancel switch assembly) is turned from off to on.
Check that the blind spot monitor indicator on the blind spot monitor main switch (warning cancel switch assembly) turns off normally when the blind spot monitor main switch (warning cancel switch assembly) is turned from on to off.
| Proceed to |
|---|
| The blind spot monitor indicator operates normally |
| The blind spot monitor indicator does not operate normally |
The blind spot monitor indicator operates normally
The blind spot monitor indicator does not operate normally
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind spot monitor Master / Data List.
According to the display on Techstream, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Main Switch | Blind spot monitor main switch (warning cancel switch assembly) | OFF or ON | ON: Blind spot monitor main switch (warning cancel switch assembly) on
OFF: Blind spot monitor main switch (warning cancel switch assembly) off |
- |
| Tester Display |
|---|
| Main Switch |
| Result | Proceed to |
|---|---|
| The display does not change as shown above when the blind spot monitor main switch (warning cancel switch assembly) is operated. | A |
| The display changes as shown above when the blind spot monitor main switch (warning cancel switch assembly) is operated. | B |
A
B
Remove the blind spot monitor main switch (warning cancel switch assembly).
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>REAR CROSS TRAFFIC ALERT BUZZER>REMOVAL
Inspect the blind spot monitor main switch (warning cancel switch assembly).
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR MAIN SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>REAR CROSS TRAFFIC ALERT BUZZER>REMOVAL
Disconnect the G75 blind spot monitor main switch (warning cancel switch assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G75-11 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| G75-11 (B) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the R1 blind spot monitor sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| R1-8 (BSSW) - G75-8 (D) | Always | Below 1 Ω |
| R1-8 (BSSW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the blind spot monitor main switch (warning cancel switch assembly).
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>REAR CROSS TRAFFIC ALERT BUZZER>REMOVAL
Inspect the blind spot monitor main switch (warning cancel switch assembly).
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR MAIN SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>REAR CROSS TRAFFIC ALERT BUZZER>REMOVAL
Disconnect the R1 blind spot monitor sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| R1-3 (BIND) - G75-12 (E) | Always | Below 1 Ω |
| R1-3 (BIND) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG