The cooler (ambient temperature sensor) thermistor is installed in front of the cooler condenser assembly to detect the ambient temperature which is used to control the air conditioning system. This sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the combination meter assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies voltage (5 V) to the cooler (ambient temperature sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (ambient temperature sensor) thermistor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1412 | Ambient Temperature Sensor Circuit | Open or short in cooler (ambient temperature sensor) thermistor circuit | ·
Cooler (ambient temperature sensor) thermistor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Combination meter assembly ·
CAN communication system |
Memorized
(4 seconds or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the ambient temperature is approximately -52.9°C (-63.22°F) or less, DTC B1412 may be output even though the system is normal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Tester Display |
|---|
| Ambient Temp Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
Remove the cooler (ambient temperature sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
Inspect the cooler (ambient temperature sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G16 combination meter assembly connector.
Disconnect the A26 cooler (ambient temperature sensor) thermistor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-35 (TX1+) - A26-2 (SO+) | Always | Below 1 Ω |
| G16-34 (TX1-) - A26-1 (SO-) | Always | Below 1 Ω |
| G16-35 (TX1+) - Body ground | Always | 10 kΩ or higher |
| G16-34 (TX1-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the combination meter assembly.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER>REMOVAL
Since the combination meter assembly cannot be inspected while it is removed from the vehicle, replace the combination meter assembly with a new or known good one and check that the condition returns to normal.
Check for DTCs.
| Proceed to |
|---|
| DTC B1412 is not output |
| DTC B1412 is output |
DTC B1412 is not output
DTC B1412 is output