Home › Power Source / Network › POWER DISTRIBUTION › MAIN BODY ECU
RM30B0U _57 Power Source / Network _009132 POWER DISTRIBUTION _0057948 MAIN BODY ECU A

POWER DISTRIBUTION  MAIN BODY ECU  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 3.REMOVE UPPER INSTRUMENT PANEL SUB-ASSEMBLY

Hide 5.REMOVE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

a.
E269526

Disconnect the connectors.


b.

Remove the 2 bolts and instrument panel junction block assembly.


Hide 6.REMOVE MULTIPLEX NETWORK BODY ECU (MAIN BODY ECU)

a.
E270636
1.542,2.385 2.094,1.99 true 0.333,2.792 0.625,2.792 true 0.76,2.625 1.385,2.896 true 0.167,2.698 0.479,2.854 0.313,0.156 10 *1 1.438,2.844 1.75,3 0.313,0.156 10 *2 1.365,2.344 1.677,2.5 0.313,0.156 10 *3
*1 Multiplex Network Body ECU (Main Body ECU)
*2 Claw of Junction Block
*3 Protective Tape


Press the claw of the junction block as shown in the illustration to release the lock.


b.

With the junction block lock released, insert a screwdriver with its tip wrapped with protective tape horizontally between the multiplex network body ECU (main body ECU) and junction block.

NOTICE:

Use a screwdriver with a diameter of between 5.0 mm (0.197 in.) and 6.3 mm (0.248 in.) and a length of approximately 90 mm (3.54 in.).



c.
E270638
1.146,1.646 1.792,1.375 true 0.948,1.583 1.26,1.74 0.313,0.156 10 *1
*1 Protective Tape


Using the screwdriver, carefully raise the multiplex network body ECU (main body ECU) up to the position where the connector becomes disengaged.

NOTICE:
·

Do not insert the screwdriver opening between the junction block and the connector of the multiplex network body ECU (main body ECU).

·

Do not twist the screwdriver to raise the multiplex network body ECU (main body ECU).




d.
E270640
2.229,1.344 2.688,1.542 0.458,0.198 10 (2) 0.927,1.146 1.385,1.344 0.458,0.198 10 (1)

Raise the multiplex network body ECU (main body ECU) as shown by the arrow (1), and then pull it out as shown by the arrow (2) in the illustration.

NOTICE:

Do not touch the ECU connector.