The cooler (ambient temperature sensor) thermistor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioning system AUTO mode. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the cooler (ambient temperature sensor) thermistor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler (ambient temperature sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (ambient temperature sensor) thermistor. The combination meter assembly sends the read signal to the air conditioning amplifier via CAN communication.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| B1412/12 | Ambient Temperature Sensor Circuit | Open or short in cooler (ambient temperature sensor) thermistor circuit | ·
Cooler (ambient temperature sensor) thermistor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Combination meter assembly |
Memorized (4 seconds or more) | - |
The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.
If the ambient temperature is approximately -52.9°C (-63.22°F) or less, DTC B1412/12 may be output even though the system is normal.
When the battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Cooler (ambient temperature sensor) thermistor | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Tester Display |
|---|
| Ambient Temp Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
Remove the cooler (ambient temperature sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
Inspect the cooler (ambient temperature sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A26 cooler (ambient temperature sensor) thermistor connector.
Disconnect the G16 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A26-1 (SO-) - G16-34 (TX1-) | Always | Below 1 Ω |
| A26-2 (SO+) - G16-35 (TX1+) | Always | Below 1 Ω |
| A26-1 (SO-) - Body ground | Always | 10 kΩ or higher |
| A26-2 (SO+) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG