Shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2769 | Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) | The ECM detects a short in the shift solenoid valve SL circuit when shift solenoid valve SL is operated (2-trip detection logic). | ·
Short in shift solenoid valve SL circuit ·
Shift solenoid valve SL ·
Wiring harness connector ·
ECM |
Comes on | DTC stored |
| P2770 | Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) | The ECM detects an open in the shift solenoid valve SL circuit when shift solenoid valve SL is not operated (2-trip detection logic). | ·
Open in shift solenoid valve SL circuit ·
Shift solenoid valve SL ·
Wiring harness connector ·
ECM |
Comes on | DTC stored |
Fail-safe function:
If the ECM detects a malfunction, it turns shift solenoid valve SL off.
Based on the signals from the throttle position sensor, air flow meter and crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smooth torque converter engagement. Shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift solenoid valve SL, it will illuminate the MIL and store the DTC.
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click hereDrivetrain>U760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B77-3 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B78 wiring harness connector.
Disconnect the B77 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B78-6 (SL) - B77-3 (SL) | Always | Below 1 Ω |
| B78-6 (SL) or B77-3 (SL) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Remove the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-6 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SL |
Remove shift solenoid valve SL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Shift solenoid valve SL connector terminal - Shift solenoid valve SL body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve SL connector ·
Battery negative (-) → Shift solenoid valve SL body |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG