Home › Power Source / Network › 2AR-FE BATTERY / CHARGING › CHARGING SYSTEM
RM3090E _57 Power Source / Network _008403 2AR-FE BATTERY / CHARGING _0046917 CHARGING SYSTEM C

2AR-FE BATTERY / CHARGING  CHARGING SYSTEM  P161A  LIN Communication Error with Alternator  


DESCRIPTION

The generator control ECU assembly and generator assembly detect reception errors respectively. The generator assembly reception error detected by the generator assembly is sent to the generator control ECU assembly via LIN communication. If an error occurs in the generator control ECU assembly or generator assembly, the generator control ECU assembly determines there is a LIN communication error and stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P161A LIN Communication Error with Alternator A reception error in the generator control ECU assembly or generator assembly continues for approximately 17 minutes or more with the ignition switch ON
(1 trip detection logic)
·

Wire harness or connector

·

Generator assembly

·

Generator control ECU assembly


Come on DTC stored

WIRING DIAGRAM

E221308E03
1.469,1.021 1.76,1.208 0.292,0.188 10 false LIN 5.667,1.01 6.031,1.188 0.365,0.177 10 false LIN1 1.771,0.854 1.927,1.052 0.156,0.198 10 false 1 5.448,0.854 5.604,1.052 0.156,0.198 10 false 6 0.708,1.833 1.021,2.031 0.313,0.198 10 false B62 5.271,1.99 6.948,2.594 1.677,0.604 10 false Generator Control ECU Assembly (Battery Current Sensor) 5.271,1.813 5.604,1.99 0.333,0.177 10 false A58 0.927,2.344 2.583,2.583 1.656,0.24 10 false : LIN Communication Line 0.698,2 2.021,2.198 1.323,0.198 10 false Generator Assembly

PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR) - GENERATOR ASSEMBLY)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR) - GENERATOR ASSEMBLY)
a.

Disconnect the A58 generator control ECU assembly connector.


b.

Disconnect the B62 generator assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
A58-6 (LIN1) - B62-1 (LIN) Always Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
A58-6 (LIN1) or B62-1 (LIN) - Body ground Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher



Result:
Result
OK
NG



OK

3.INSPECT GENERATOR ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT GENERATOR ASSEMBLY

Result:
Result
OK
NG



OK

REPLACE GENERATOR CONTROL ECU ASSEMBLY (BATTERY CURRENT SENSOR)

NG