When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.
| Oper Permission (Battery) | Oper Permission (Start Min Volt 1) | Oper Permission (Start Min Volt 2) | Oper Permission (Start Min Volt 3) |
| Oper Permission (Start Min Volt 4) | Oper Permission (Battery Current) | Oper Permission (Integrated Current) | Oper Prohibition (Jump Start) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
| Proceed to |
|---|
| DTCs are not output |
| DTCs are output |
DTCs are not output
DTCs are output
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery condition | NG / OK | OK: Stop and start control is permitted based on battery condition, or Active Test (forced permission) is performed | - |
| Oper Permission (Start Min Volt 1) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 2) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 3) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 4) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Battery Current) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery discharge current is -125 A or higher | Engine stop and start ECU calculated value |
| Oper Permission (Integrated Current) | Permission of stop and start control based on the integrated current value condition | NG / OK | OK: Integrated current value more than specified | The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature. |
| Oper Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start condition | Permit / Prohibit | Prohibit: Engine started with the engine hood open and the ignition switch turned START | When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off. |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Oper Permission (Start Min Volt 1) |
| Oper Permission (Start Min Volt 2) |
| Oper Permission (Start Min Volt 3) |
| Oper Permission (Start Min Volt 4) |
| Oper Permission (Battery Current) |
| Oper Permission (Integrated Current) |
| Oper Prohibition (Jump Start) |
| Proceed to |
|---|
| NEXT |
NEXT
Check whether stop and start control was prohibited based on the battery conditions or other conditions.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Type | Range | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
NG is displayed
OK is displayed
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>SYSTEM DESCRIPTION
Check whether stop and start control was prohibited based on the battery charge control mode.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Status of Battery Charge Control | Battery charge control status | Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode | - | - |
| Tester Display |
|---|
| Status of Battery Charge Control |
| Result | Proceed to |
|---|---|
| "Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed | A |
| "Refresh Charge Mode" is displayed | B |
| "Abnormal Mode" is displayed | C |
| "Battery Condition Judgment Mode" is displayed | D |
If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.
A
B
C
D
Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery
Other: Non-specified battery |
- |
| Oper Permission (Start Min Volt 1) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 2) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 3) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Oper Permission (Start Min Volt 4) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold | If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted |
| Tester Display |
|---|
| Battery Type |
| Oper Permission (Start Min Volt 1) |
| Oper Permission (Start Min Volt 2) |
| Oper Permission (Start Min Volt 3) |
| Oper Permission (Start Min Volt 4) |
| Proceed to |
|---|
| OK is displayed for 2 or more items |
| OK is displayed for 1 item or none |
The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Temp (Start) | Battery temperature at engine start | Min.: -40°C (-40°F)
Max.: 100°C (212°F) |
Same as temperature around battery at engine start (after engine start) | - |
| Min Voltage(Cranking) | Minimum voltage when cranking engine | Min.: 0 V
Max.: 327.67 V |
6 to 11 V | Lowest battery voltage measured in a 5 second period after the starter starts operating. |
| Min Volt(After Cranking) | Minimum voltage when starter begins operation | Min.: 0 V
Max.: 327.67 V |
6 to 11 V | Minimum battery voltage while starter driving |
| Tester Display |
|---|
| Battery Temp (Start) |
| Min Voltage(Cranking) |
| Min Volt(After Cranking) |
| Tester Display | Starting Battery Voltage | Battery Temperature* |
|---|---|---|
| Oper Permission (Start Min Volt 1) | 7.65 V or higher | 0°C (32°F) or lower |
| Oper Permission (Start Min Volt 2) | 7.65 V or higher | Higher than 0°C (32°F) |
| Oper Permission (Start Min Volt 3) | 7.66 V or higher | 0°C (32°F) or lower |
| Oper Permission (Start Min Volt 4) | 7.66 V or higher | Higher than 0°C (32°F) |
*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
| Tester Display | Starting Battery Voltage | Battery Temperature* |
|---|---|---|
| Oper Permission (Start Min Volt 1) | 8.92 V or higher | 0°C (32°F) or lower |
| Oper Permission (Start Min Volt 2) | 8.92 V or higher | Higher than 0°C (32°F) |
| Oper Permission (Start Min Volt 3) | 8.92 V or higher | 0°C (32°F) or lower |
| Oper Permission (Start Min Volt 4) | 8.92 V or higher | Higher than 0°C (32°F) |
*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
OK is displayed for 2 or more items
OK is displayed for 1 item or none
Check whether stop and start control was prohibited based on the battery discharge current battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery Current) | Permission of stop and start control based on the battery condition | NG / OK | OK: Battery discharge current is -125 A or higher | Engine stop and start ECU calculated value |
| Tester Display |
|---|
| Oper Permission (Battery Current) |
| Proceed to |
|---|
| OK is displayed |
| NG is displayed |
The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Current | Battery current | Min.: -125 A
Max.: 124.99 A |
- | - |
| Tester Display |
|---|
| Battery Current |
| Tester Display | Battery Current |
|---|---|
| Oper Permission (Battery Current) | -125 A or higher |
OK is displayed
NG is displayed
Check whether stop and start control was prohibited based on the integrated current value battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Integrated Current) | Permission of stop and start control based on the integrated current value condition | NG / OK | OK: Integrated current value more than specified | The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the battery temperature. |
| Tester Display |
|---|
| Oper Permission (Integrated Current) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
NG is displayed
OK is displayed
Judge the battery condition based on the integrated current value.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Integrated Current | Battery integrated current | Min.: -268434.45 A-sec
Max.: 268435.45 A-sec |
Differs according to the vehicle condition (charge / discharge conditions) | - |
| Tester Display |
|---|
| Integrated Current |
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Fluid Temperature | Battery temperature | Min.: -40°C (-40°F)
Max.: 100°C (212°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Idle | Engine idling status | ON / OFF | ON: Accelerator pedal fully released
OFF: Accelerator pedal depressed |
This is sent from the ECM. |
| Battery Current | Battery current | Min.: -125 A
Max.: 124.99 A |
- | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F) |
Close to ambient air temperature | - |
| Integrated Current | Battery integrated current | Min.: -268434.45 A-sec
Max.: 268435.45 A-sec |
Differs according to the vehicle condition (charge / discharge conditions) | - |
| Tester Display |
|---|
| Battery Fluid Temperature |
| Idle |
| Battery Current |
| Ambient Temp Sensor |
| Integrated Current |
| Status of Battery Charge Control | Battery Fluid Temperature | Integrated Current | Proceed to |
|---|---|---|---|
| Charge Control Coordination Mode or Stop and Start Standalone Mode | - | Below -13478 A-sec | A |
| Low Temperature Mode | Between 3°C (37.4°F) and 11°C (51.8°F) | Below -6048 A-sec | |
| Low Temperature Mode | Between -1°C (30.2°F) and under 3°C (37.4°F) | Below -3974 A-sec | |
| Stop and Start Restriction Mode or Temperature High/Low Mode | -15°C (5°F) or higher or below 75°C (167°F) | Below 0 A-sec | |
| Stop and Start Restriction Mode or Temperature High/Low Mode | Below -15°C (5°F) or 75°C (167°F) or higher | - | B |
| Result | Cause | Action to be Taken |
|---|---|---|
| A | Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery | Check the battery condition and recharge or replace the battery |
| B | Integrated current value is limited for stop and start control due to battery temperature (too high/low) | Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery. |
Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).
*: Use the GTS to perform Integrated Current Value Initialization.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION
If the Data List item "Integrated Current" is 0 or higher, it is not necessary to perform initialization.
When the battery state sensor assembly current value is normal, recharge or replace the battery
| Proceed to |
|---|
| NEXT |
NEXT
Check the operation of the backup boost converter.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| State of BBC | Backup boost converter status | Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status | Normal: Backup boost converter operating normally | ·
Cycle Err: ·
Abnormal output voltage cycle is detected ·
Overvol: ·
When the ignition switch is ON: 1.
Overvoltage is detected at the control IC power source within the backup boost converter 2.
Overheating is detected at the control IC power source within the backup boost converter ·
When boosting: 1.
Malfunction is detected in the feedback circuit in the backup boost converter 2.
Too high or low output voltage ·
Overload: ·
Overcurrent is detected. ·
Low Vol: ·
A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON. ·
Duty Err: ·
Abnormal duty ratio is detected |
| BBC Check Result | Backup boost converter check result | Normal / Abnormal | - | - |
| Tester Display |
|---|
| State of BBC |
| BBC Check Result |
| Proceed to |
|---|
| Normal is displayed |
| Normal is not displayed |
Normal is displayed
Normal is not displayed
Check whether stop and start control was prohibited based on the jump start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Prohibition (Jump Start) | Prohibition of stop and start control based on the jump start condition | Permit / Prohibit | Prohibit: Engine started with the engine hood open and the ignition switch turned START | When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off. |
| Tester Display |
|---|
| Oper Prohibition (Jump Start) |
| Proceed to |
|---|
| Permit is displayed |
| Prohibit is displayed |
The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed
OFF: Engine hood open |
- |
| Oper Permission (Engine Hood Closed) | Permission of stop and start control based on the engine hood open/close condition | NG / OK | OK: Engine hood closed | - |
| Tester Display |
|---|
| Hood Courtesy Switch |
| Oper Permission (Engine Hood Closed) |
| Tester Display | Conditions |
|---|---|
| Oper Prohibition (Jump Start) | OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed) |
A jump start is determined if the engine is started with the engine hood open.
Replace if the battery is deteriorated.
A jump start determination is canceled if the engine is started with the engine hood closed after the ignition switch is turned off.
Permit is displayed
Prohibit is displayed
Check whether stop and start control was prohibited based on the battery temperature battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery conditions | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Fluid Temperature | Battery temperature | Min.: -40°C (-40°F)
Max.: 100°C (212°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F) |
Close to ambient temperature | - |
| Tester Display |
|---|
| Battery Fluid Temperature |
| Ambient Temp Sensor |
| Tester Display | Battery Temperature* |
|---|---|
| Oper Permission (Battery) | Current battery temperature is between -10°C (14°F) and 70°C (158°F) |
*: Read the Data List items "Battery Fluid Temperature" and "Ambient Temp Sensor" when checking the battery temperature.
NG is displayed
OK is displayed
Check the battery temperature.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Fluid Temperature | Battery temperature | Min.: -40°C (-40°F)
Max.: 100°C (212°F) |
Changes according to actual temperature: Driving after engine warmed up | - |
| Ambient Temp Sensor | Ambient temperature | Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F) |
Close to ambient temperature | - |
| Tester Display |
|---|
| Battery Fluid Temperature |
| Ambient Temp Sensor |
| Proceed to | Proceed to |
|---|---|
| Both Battery Fluid Temperature and Ambient Temp Sensor are suitable temperature | A |
| Battery Fluid Temperature or Ambient Temp Sensor is not suitable temperature | B |
If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.
A
B
Check whether stop and start control was prohibited based on the alternator status battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery condition | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Alternator Status | Generator power generation status | Normal / Abnormal | Normal: Generator operation normal | - |
| Tester Display |
|---|
| Alternator Status |
| Tester Display | Conditions |
|---|---|
| Oper Permission (Battery) | Normal is displayed for Alternator Status (Generator is generating power) |
| Charge indicator is off when the engine is running (Generator is generating power) |
NG is displayed
OK is displayed
Check the power generation status of the generator.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Alternator Status | Generator power generation status | Normal / Abnormal | Normal: Generator operation normal | - |
| Tester Display |
|---|
| Alternator Status |
| Proceed to |
|---|
| Normal is displayed |
| Abnormal is displayed |
Normal is displayed
Abnormal is displayed
Check whether stop and start control was prohibited based on the idling stop rate battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Oper Permission (Battery) | Permission of stop and start control based on the battery condition | NG / OK | OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed | - |
| Tester Display |
|---|
| Oper Permission (Battery) |
| Proceed to |
|---|
| NG is displayed |
| OK is displayed |
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Idling Stop Rate | Rate of the idling stop time to the entire ignition switch ON time | Min.: 0%
Max.: 100% |
- | - |
| Total Idling Stop Rate | Rate of total idling stop time | Min.: 0%
Max.: 100% |
- | - |
| Tester Display |
|---|
| Idling Stop Rate |
| Total Idling Stop Rate |
| Tester Display | Conditions |
|---|---|
| Oper Permission (Battery) | Idling Stop Rate is 50% or less and Total Idling Stop Rate is 40% or less |
Once the threshold is exceeded, stop and start will be permitted again once Idling Stop Rate reaches 47% or less and Total Idling Stop Rate reaches 40% or less.
NG is displayed
OK is displayed
Check the idling stop rate.
Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate and Total Idling Stop Rate.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Idling Stop Rate | Rate of the idling stop time to the entire ignition switch ON time | Min.: 0%
Max.: 100% |
- | - |
| Total Idling Stop Rate | Rate of total idling stop time | Min.: 0%
Max.: 100% |
- | - |
| Tester Display |
|---|
| Idling Stop Rate |
| Total Idling Stop Rate |
| Result | Proceed to |
|---|---|
| Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher | A |
| Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower | B |
If Idling Stop Rate is higher than 50% or Total Idling Stop Rate is higher than 40%, turn the ignition switch off and leave the vehicle off for a while. After that, restart the engine. If the Data List item "Oper Permission (Battery)" still shows not permitted, the battery may be degraded or temporarily discharging. In that case, charge or replace the battery after checking the battery state.
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check the "Battery Type" Data List Item.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery
Other: Non-specified battery |
- |
| Tester Display |
|---|
| Battery Type |
Check whether the battery is specified or not specified.
| Data List Battery Type Display | Equipped Battery | Proceed to |
|---|---|---|
| Other | Specified battery | A |
| Other | Non-specified battery | B |
| Specified | - | C |
A
B
C
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.
| Tester Display |
|---|
| Switch Battery Type |
Perform Switch Battery Type under Utility and set the Specified battery.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check that the "Battery Type" Data List item is set to "Specified".
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Type | Set battery type | Specified / Other | Specified: Specified battery
Other: Non-specified battery |
- |
| Tester Display |
|---|
| Battery Type |
| Proceed to |
|---|
| NEXT |
NEXT
Before performing this step, check that the engine hood can be opened by pulling the hood lock control cable.
Check the engine hood courtesy switch (hood lock assembly).
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Hood Courtesy Switch | Hood courtesy switch signal | ON / OFF | ON: Engine hood closed
OFF: Engine hood opened |
- |
| Tester Display |
|---|
| Hood Courtesy Switch |
| Proceed to |
|---|
| OK |
| NG |
If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
OK
NG