Home › Engine / Hybrid System › STOP AND START › STOP AND START SYSTEM(for 3ZR-FAE) › 2015.04–2015.10
RM3090E _51 Engine / Hybrid System _009049 STOP AND START _0166176 STOP AND START SYSTEM(for 3ZR-FAE) J

STOP AND START  STOP AND START SYSTEM(for 3ZR-FAE)  Stop and Start System does not Operate (Battery Condition)  


DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.

HINT:
Data List items
Oper Permission (Battery) Oper Permission (Start Min Volt 1) Oper Permission (Start Min Volt 2) Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4) Oper Permission (Battery Current) Oper Permission (Integrated Current) Oper Prohibition (Jump Start)


PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Trouble Codes.


e.

Read the DTCs.

Powertrain > Stop and Start > Trouble Codes
50001 227
Result:
Proceed to
DTCs are not output
DTCs are output




DTCs are not output

2.READ VALUE USING GTS

DTCs are output

2.READ VALUE USING GTS
a.

Enter the following menus: Powertrain / Stop and Start / Data List.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery condition NG / OK OK: Stop and start control is permitted based on battery condition, or Active Test (forced permission) is performed -
Oper Permission (Start Min Volt 1) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Battery Current) Permission of stop and start control based on the battery condition NG / OK OK: Battery discharge current is -125 A or higher Engine stop and start ECU calculated value
Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value condition NG / OK OK: Integrated current value more than specified The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.
Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned START When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Oper Permission (Battery Current)
Oper Permission (Integrated Current)
Oper Prohibition (Jump Start)
50003 227 120,124,123,122,121,125,126,128

Result:
Proceed to
NEXT



NEXT

3.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
3.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
HINT:

Check whether stop and start control was prohibited based on the battery conditions or other conditions.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Type Range Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed -
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
50003 227 120
Result:
Proceed to
NG is displayed
OK is displayed




NG is displayed

4.READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)

OK is displayed

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

4.READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)
HINT:

Check whether stop and start control was prohibited based on the battery charge control mode.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Status of Battery Charge Control Battery charge control status Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode - -
Powertrain > Stop and Start > Data List
Tester Display
Status of Battery Charge Control
50003 227 273
Result:
Result Proceed to
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed A
"Refresh Charge Mode" is displayed B
"Abnormal Mode" is displayed C
"Battery Condition Judgment Mode" is displayed D


HINT:

If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.




A

5.READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))

B

END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)

C

D

END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE)

5.READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))
HINT:

Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Oper Permission (Start Min Volt 1) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4) Permission of stop and start control based on the battery condition NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
50003 227 421,124,123,122,121
Result:
Proceed to
OK is displayed for 2 or more items
OK is displayed for 1 item or none


i.

The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Same as temperature around battery at engine start (after engine start) -
Min Voltage(Cranking) Minimum voltage when cranking engine Min.: 0 V
Max.: 327.67 V
6 to 11 V Lowest battery voltage measured in a 5 second period after the starter starts operating.
Min Volt(After Cranking) Minimum voltage when starter begins operation Min.: 0 V
Max.: 327.67 V
6 to 11 V Minimum battery voltage while starter driving
Powertrain > Stop and Start > Data List
Tester Display
Battery Temp (Start)
Min Voltage(Cranking)
Min Volt(After Cranking)
50003 227 153,67,210
Permission Criteria (Specified Battery):
Tester Display Starting Battery Voltage Battery Temperature*
Oper Permission (Start Min Volt 1) 7.65 V or higher 0°C (32°F) or lower
Oper Permission (Start Min Volt 2) 7.65 V or higher Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) 7.66 V or higher 0°C (32°F) or lower
Oper Permission (Start Min Volt 4) 7.66 V or higher Higher than 0°C (32°F)


*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.


Permission Criteria (Non-specified Battery):
Tester Display Starting Battery Voltage Battery Temperature*
Oper Permission (Start Min Volt 1) 8.92 V or higher 0°C (32°F) or lower
Oper Permission (Start Min Volt 2) 8.92 V or higher Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) 8.92 V or higher 0°C (32°F) or lower
Oper Permission (Start Min Volt 4) 8.92 V or higher Higher than 0°C (32°F)


*: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.





OK is displayed for 2 or more items

6.READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))

OK is displayed for 1 item or none

17.READ VALUE USING GTS (BATTERY TYPE)
6.READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))
HINT:

Check whether stop and start control was prohibited based on the battery discharge current battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery Current) Permission of stop and start control based on the battery condition NG / OK OK: Battery discharge current is -125 A or higher Engine stop and start ECU calculated value
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery Current)
50003 227 125
Result:
Proceed to
OK is displayed
NG is displayed


i.

The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Current Battery current Min.: -125 A
Max.: 124.99 A
- -
Powertrain > Stop and Start > Data List
Tester Display
Battery Current
50003 227 60
Permission Criteria:
Tester Display Battery Current
Oper Permission (Battery Current) -125 A or higher





OK is displayed

7.READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))

NG is displayed

END (REDUCE ELECTRICAL LOAD)

7.READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))
HINT:

Check whether stop and start control was prohibited based on the integrated current value battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value condition NG / OK OK: Integrated current value more than specified The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the battery temperature.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Integrated Current)
50003 227 126
Result:
Proceed to
NG is displayed
OK is displayed




NG is displayed

8.READ VALUE USING GTS (INTEGRATED CURRENT)

OK is displayed

9.READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)
8.READ VALUE USING GTS (INTEGRATED CURRENT)
HINT:

Judge the battery condition based on the integrated current value.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Integrated Current Battery integrated current Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions) -
Powertrain > Stop and Start > Data List
Tester Display
Integrated Current
50003 227 65
i.

Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Battery temperature Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up -
Idle Engine idling status ON / OFF ON: Accelerator pedal fully released
OFF: Accelerator pedal depressed
This is sent from the ECM.
Battery Current Battery current Min.: -125 A
Max.: 124.99 A
- -
Ambient Temp Sensor Ambient temperature Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient air temperature -
Integrated Current Battery integrated current Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions) -
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Idle
Battery Current
Ambient Temp Sensor
Integrated Current
50003 227 302,20,60,63,65
Standard Integrated Current Value:
Status of Battery Charge Control Battery Fluid Temperature Integrated Current Proceed to
Charge Control Coordination Mode or Stop and Start Standalone Mode - Below -13478 A-sec A
Low Temperature Mode Between 3°C (37.4°F) and 11°C (51.8°F) Below -6048 A-sec
Low Temperature Mode Between -1°C (30.2°F) and under 3°C (37.4°F) Below -3974 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode -15°C (5°F) or higher or below 75°C (167°F) Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode Below -15°C (5°F) or 75°C (167°F) or higher - B


Cause and Action to be Taken:
Result Cause Action to be Taken
A Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery Check the battery condition and recharge or replace the battery
B Integrated current value is limited for stop and start control due to battery temperature (too high/low) Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.


·

Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).

*: Use the GTS to perform Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION

HINT:

If the Data List item "Integrated Current" is 0 or higher, it is not necessary to perform initialization.


·

When the battery state sensor assembly current value is normal, recharge or replace the battery




Result:
Proceed to
NEXT



NEXT

END (RECHARGE OR REPLACE BATTERY)

9.READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)
HINT:

Check the operation of the backup boost converter.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
State of BBC Backup boost converter status Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status Normal: Backup boost converter operating normally
·

Cycle Err:

·

Abnormal output voltage cycle is detected


·

Overvol:

·

When the ignition switch is ON:

1.

Overvoltage is detected at the control IC power source within the backup boost converter

2.

Overheating is detected at the control IC power source within the backup boost converter



·

When boosting:

1.

Malfunction is detected in the feedback circuit in the backup boost converter

2.

Too high or low output voltage



·

Overload:

·

Overcurrent is detected.


·

Low Vol:

·

A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.


·

Duty Err:

·

Abnormal duty ratio is detected



BBC Check Result Backup boost converter check result Normal / Abnormal - -
Powertrain > Stop and Start > Data List
Tester Display
State of BBC
BBC Check Result
50003 227 69,70
Result:
Proceed to
Normal is displayed
Normal is not displayed




Normal is displayed

10.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

Normal is not displayed

10.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))
HINT:

Check whether stop and start control was prohibited based on the jump start battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned START When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Jump Start)
50003 227 128
Result:
Proceed to
Permit is displayed
Prohibit is displayed


i.

The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Hood Courtesy Switch Hood courtesy switch signal ON / OFF ON: Engine hood closed
OFF: Engine hood open
-
Oper Permission (Engine Hood Closed) Permission of stop and start control based on the engine hood open/close condition NG / OK OK: Engine hood closed -
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
Oper Permission (Engine Hood Closed)
50003 227 8,111
Permission Criteria:
Tester Display Conditions
Oper Prohibition (Jump Start) OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed)


HINT:
·

A jump start is determined if the engine is started with the engine hood open.

·

Replace if the battery is deteriorated.

·

A jump start determination is canceled if the engine is started with the engine hood closed after the ignition switch is turned off.






Permit is displayed

11.READ VALUE USING GTS (OPER PERMISSION (BATTERY))

Prohibit is displayed

19.READ VALUE USING GTS (HOOD COURTESY SWITCH)
11.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
HINT:

Check whether stop and start control was prohibited based on the battery temperature battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
50003 227 120
Result:
Proceed to
NG is displayed
OK is displayed


i.

The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Battery temperature Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up -
Ambient Temp Sensor Ambient temperature Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient temperature -
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
50003 227 302,63
Permission Criteria:
Tester Display Battery Temperature*
Oper Permission (Battery) Current battery temperature is between -10°C (14°F) and 70°C (158°F)


HINT:

*: Read the Data List items "Battery Fluid Temperature" and "Ambient Temp Sensor" when checking the battery temperature.





NG is displayed

12.READ VALUE USING GTS (BATTERY FLUID TEMPERATURE)

OK is displayed

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

12.READ VALUE USING GTS (BATTERY FLUID TEMPERATURE)
HINT:

Check the battery temperature.


a.

Enter the following menus: Powertrain / Stop and Start / Data List.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Battery temperature Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up -
Ambient Temp Sensor Ambient temperature Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient temperature -
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
50003 227 302,63
Result:
Proceed to Proceed to
Both Battery Fluid Temperature and Ambient Temp Sensor are suitable temperature A
Battery Fluid Temperature or Ambient Temp Sensor is not suitable temperature B


HINT:

If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.




A

13.READ VALUE USING GTS (OPER PERMISSION (BATTERY))

B

END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE)

13.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
HINT:

Check whether stop and start control was prohibited based on the alternator status battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery condition NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
50003 227 120
Result:
Proceed to
NG is displayed
OK is displayed


i.

The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Alternator Status Generator power generation status Normal / Abnormal Normal: Generator operation normal -
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
50003 227 298
Permission Criteria:
Tester Display Conditions
Oper Permission (Battery) Normal is displayed for Alternator Status (Generator is generating power)
Charge indicator is off when the engine is running (Generator is generating power)





NG is displayed

14.READ VALUE USING GTS (ALTERNATOR STATUS)

OK is displayed

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

14.READ VALUE USING GTS (ALTERNATOR STATUS)
HINT:

Check the power generation status of the generator.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Alternator Status Generator power generation status Normal / Abnormal Normal: Generator operation normal -
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
50003 227 298
Result:
Proceed to
Normal is displayed
Abnormal is displayed




Normal is displayed

15.READ VALUE USING GTS (OPER PERMISSION (BATTERY))

Abnormal is displayed

15.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
HINT:

Check whether stop and start control was prohibited based on the idling stop rate battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery condition NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
50003 227 120
Result:
Proceed to
NG is displayed
OK is displayed


i.

The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time Min.: 0%
Max.: 100%
- -
Total Idling Stop Rate Rate of total idling stop time Min.: 0%
Max.: 100%
- -
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
50003 227 176,272
Permission Criteria:
Tester Display Conditions
Oper Permission (Battery) Idling Stop Rate is 50% or less and Total Idling Stop Rate is 40% or less


HINT:

Once the threshold is exceeded, stop and start will be permitted again once Idling Stop Rate reaches 47% or less and Total Idling Stop Rate reaches 40% or less.





NG is displayed

16.READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)

OK is displayed

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

16.READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)
HINT:

Check the idling stop rate.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate and Total Idling Stop Rate.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time Min.: 0%
Max.: 100%
- -
Total Idling Stop Rate Rate of total idling stop time Min.: 0%
Max.: 100%
- -
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
50003 227 176,272
Result:
Result Proceed to
Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher A
Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower B


HINT:

If Idling Stop Rate is higher than 50% or Total Idling Stop Rate is higher than 40%, turn the ignition switch off and leave the vehicle off for a while. After that, restart the engine. If the Data List item "Oper Permission (Battery)" still shows not permitted, the battery may be degraded or temporarily discharging. In that case, charge or replace the battery after checking the battery state.




A

END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE 50% OR MORE OR TOTAL IDLING STOP RATE 40% OR MORE)

B

CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)

17.READ VALUE USING GTS (BATTERY TYPE)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.


e.

Check the "Battery Type" Data List Item.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 227 421

f.

Check whether the battery is specified or not specified.


Result:
Data List Battery Type Display Equipped Battery Proceed to
Other Specified battery A
Other Non-specified battery B
Specified - C



A

18.SWITCH BATTERY TYPE

B

EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT BATTERY MALFUNCTION WHEN A NON-SPECIFIED BATTERY IS USED

C

CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)

18.SWITCH BATTERY TYPE
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.

Powertrain > Engine and ECT > Utility
Tester Display
Switch Battery Type
50005 234 4377

e.

Perform Switch Battery Type under Utility and set the Specified battery.


f.

Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.


g.

Check that the "Battery Type" Data List item is set to "Specified".

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 227 421

Result:
Proceed to
NEXT



NEXT

END

19.READ VALUE USING GTS (HOOD COURTESY SWITCH)
NOTICE:

Before performing this step, check that the engine hood can be opened by pulling the hood lock control cable.


HINT:

Check the engine hood courtesy switch (hood lock assembly).


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Hood Courtesy Switch Hood courtesy switch signal ON / OFF ON: Engine hood closed
OFF: Engine hood opened
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
50003 227 8
Result:
Proceed to
OK
NG


HINT:

If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.




OK

END (STOP AND START CONTROL PROHIBITED DUE TO ENGINE START WITH ENGINE HOOD OPEN)

NG