STOP AND START  STOP AND START SYSTEM(for 3ZR-FAE)  Starter Inrush Current Reduction Relay Circuit  


DESCRIPTION

The starter inrush current reduction relay prevents the battery voltage from becoming dropping excessively while the starter assembly is operating. If the battery voltage drops below the threshold, stop and start control will be prohibited. In order to prevent this, the engine stop and start ECU operates the starter inrush current reduction relay for approximately 0.1 seconds after the ST NO. 2 relay is activated. By allowing current to flow to the starter inrush current reduction relay, the current that flows to the starter motor is reduced, preventing the battery voltage from dropping excessively.

A285269E08
0.792,0.979 1.656,1.302 0.865,0.323 10 false from Battery 0.26,2.635 1.698,2.948 1.438,0.313 10 false from ST NO. 1 Relay 2.469,0.875 2.813,1.104 0.344,0.229 10 false B 2.458,1.188 3,1.49 0.542,0.302 10 false SL2 2.469,2.521 2.917,2.802 0.448,0.281 10 false SL1 0.156,0.094 1.792,0.385 1.635,0.292 10 false Starter Assembly 4.167,1.698 6.563,1.917 2.396,0.219 10 false Starter Inrush Current Reduction Relay 0.271,1.302 1.896,1.677 1.625,0.375 10 false from ST NO. 2 Relay 3.75,0.885 3.906,1.083 0.156,0.198 10 false M 4.344,1.344 4.5,1.542 0.156,0.198 10 false S 4.313,0.49 4.469,0.688 0.156,0.198 10 false B 6.156,0.49 6.313,0.688 0.156,0.198 10 false M

CAUTION / NOTICE / HINT

HINT:
·

Starter inrush current reduction relay stuck on:

When the engine is started by stop and start control, a large amount of current will flow to the starter assembly, the battery voltage will drop excessively and stop and start control will be canceled.

·

Starter inrush current reduction relay stuck off:

Operating current will always flow through the starter inrush current reduction relay and the cranking speed will be low.



PROCEDURE

1.CHECK WAVEFORM (STARTER INRUSH CURRENT REDUCTION RELAY)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Active Test / Starter Motor Drive Magnet Switch / Data List / Min Volt(After Cranking).


e.

Select the Data List item "Min Volt(After Cranking)".

Powertrain > Stop and Start > Active Test
Active Test Display
Starter Motor Drive Magnet Switch
Data List Display
Min Volt(After Cranking)
50004 227 13 210

f.

Connect the positive (+) lead of an oscilloscope to the positive (+) battery terminal and the negative (-) lead to the negative (-) battery terminal.


g.

While performing the Active Test "Starter Motor Drive Magnet Switch" to forcibly operate the starter motor, count the number of times the waveform drops and check the Data List item "Min Volt(After Cranking)".

NOTICE:
·

The Active Test "Starter Motor Drive Magnet Switch" is stopped automatically after the starter motor operates for 3 seconds.

·

Do not forcibly operate the starter pinion.



A285238E02
2.719,0.448 3,0.167 3,0.167 3.333,0.167 false 0.104,0.208 0.719,0.406 0.615,0.198 10 false Normal: 0.146,1.469 0.76,1.667 0.615,0.198 10 false Abnormal: 0.146,2.417 0.76,2.615 0.615,0.198 10 false Abnormal: 1.135,0.896 2.281,1.188 1.146,0.292 10 false 7.6 to 9.3 V* 0.094,0.552 1.021,0.896 0.927,0.344 10 false Approximately 12 V 3.396,0.073 5.469,0.281 2.073,0.208 10 false Approximately 0.1 seconds 2.573,1.344 4.125,1.542 1.552,0.198 10 false Less than 3 seconds 4.667,1.854 6.656,2.052 1.99,0.198 10 false : Voltage drops only 1 time 4.635,2.708 7.073,2.917 2.438,0.208 10 false : Voltage drops excessively only 1 time 4.375,3.438 6.979,3.635 2.604,0.198 10 false *: Varies with battery condition 0.146,1.813 1.073,2.156 0.927,0.344 10 false Approximately 12 V 0.146,2.719 1.073,3.063 0.927,0.344 10 false Approximately 12 V

Standard:
Specified battery:

The voltage waveform has 2 peaks and the "Min Volt (After Cranking)" Data List item (the minimum voltage after the starter begins operation) is 7.66 V or higher

Non-specified battery:

The voltage waveform has 2 peaks and the "Min Volt (After Cranking)" Data List item (the minimum voltage after the starter begins operation) is 8.92 V or higher


Result:
Number of Times Waveform Dropped Min Volt(After Cranking) (Data List Item) Proceed to
2 times 7.66 V or higher*1, 8.92 V or higher*2 A
2 times Below 7.66 V*1, Below 8.92 V*2 B
Less than 2 times 7.66 V or higher*1, 8.92 V or higher*2 C
Less than 2 times Below 7.66 V*1, Below 8.92 V*2 D


*1: Specified battery

*2: Non-specified battery




A

2.CHECK WAVEFORM (BATTERY VOLTAGE WHEN STARTER ASSEMBLY OPERATED)

B

C

REPLACE STARTER INRUSH CURRENT REDUCTION RELAY

D

REPLACE AND CHECK BATTERY

2.CHECK WAVEFORM (BATTERY VOLTAGE WHEN STARTER ASSEMBLY OPERATED)
a.

Enter the following menus: Powertrain / Stop and Start / Active Test / Starter Motor Drive Magnet Switch.


b.

Connect the positive (+) lead of an oscilloscope to the positive (+) battery terminal and the negative (-) lead to the negative (-) battery terminal. Also connect the oscilloscope to terminals A66-21 (STA) and A65-8 (GND) of the stop and start ECU.

A350366C12
1.927,0.771 2.396,1.052 0.469,0.281 3.146,0.771 3.615,1.052 0.469,0.281 2.01,1.708 1.76,2.344 true 3.354,1.698 4.031,2.323 true 0.125,0.083 0.438,0.281 0.313,0.198 10 false *a 1.563,2.396 2.01,2.583 0.448,0.188 10 false GND 2.031,0.844 2.365,1.042 0.333,0.198 10 false A65 3.26,0.844 3.594,1.042 0.333,0.198 10 false A66 3.958,2.396 4.573,2.594 0.615,0.198 10 false STA
*a Component with harness connected
(Engine Stop and Start ECU)
- -



c.

While performing the Active Test "Starter Motor Drive Magnet Switch" to forcibly operate the starter motor, measure the battery voltage.

NOTICE:

The Active Test "Starter Motor Drive Magnet Switch" is stopped automatically after the starter motor operates for 3 seconds.


A287573E10
2.729,1.948 2.917,1.667 2.917,1.667 3.167,1.667 false 2.25,3 2.083,3.417 2.083,3.417 1.833,3.417 false 3.75,2.75 4.667,3 4.667,3 4.917,3 false 0.917,1.021 1.375,1.219 0.458,0.198 10 false STA 0.167,2.031 1.135,2.396 0.969,0.365 10 false Approximately 12 V 3.25,1.573 5.25,1.75 2,0.177 10 false Approximately 0.1 seconds 4.979,2.917 7.01,3.104 2.031,0.188 10 false Less than 3 seconds 0.073,3.333 1.896,3.542 1.823,0.208 10 false Approximately 0.03 seconds 2.896,3.365 4.958,3.552 2.063,0.188 10 false Approximately 8.92 V or higher*3 4.854,0.198 6.99,0.469 2.135,0.271 10 false *1: Varies with battery condition 0.198,0.208 1.083,0.521 0.885,0.313 10 false Normal: 1.083,2.417 2.094,2.656 1.01,0.24 10 false 7.6 to 9.3 V*1 2.896,3.063 4.958,3.25 2.063,0.188 10 false Approximately 7.66 V or higher*2 4.865,0.552 6.25,0.771 1.385,0.219 10 false *2: Specified battery 4.875,0.927 6.531,1.135 1.656,0.208 10 false *3: Non-specified battery

Standard:
Specified battery:

The minimum voltage immediately after cranking is 7.66 V or higher and the voltage approximately 0.03 seconds after the ST NO. 1 relay is turned ON is approximately 7.65 V or higher

Non-specified battery:

The minimum voltage immediately after cranking is 8.92 V or higher and the voltage approximately 0.03 seconds after the ST NO. 1 relay is turned ON is approximately 8.92 V or higher


HINT:

Check the value of the following Data List items at the same time.

·

Data List [Min Voltage(Cranking)]: 7.65 V or higher*1, 8.92 V or higher*2

·

Data List [Min Volt(After Cranking)]: 7.66 V or higher*1, 8.92 V or higher*2


*1: Specified battery

*2: Non-specified battery




Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG