The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunctions detected by the ECM. When the ignition switch is turned to ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually: When the ignition switch is turned to ON, the MIL should be illuminated and should turn off after engine is started. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the GTS.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Perform troubleshooting in accordance with the table below.
| Result | Proceed to |
|---|---|
| MIL remains on | A |
| MIL does not illuminate | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Check if any DTCs have been detected. Note down any DTCs.
| Result | Proceed to |
|---|---|
| No DTC detected | A |
| Any DTCs detected | B |
Check for detected DTCs output from other ECUs which relate to the MIL.
A
B
Disconnect the A62 ECM connector.
Turn the ignition switch to ON.
Check that the MIL is not illuminated.
MIL is not illuminated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the combination meter assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-11 (CHK) or A62-27 (W) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check if the MIL is illuminated when the ignition switch is turned to ON.
MIL should be illuminated.
| Proceed to |
|---|
| OK |
| NG |
OK
(Click here Engine / Hybrid System>3ZR-FAE ENGINE CONTROL>SFI SYSTEM>CHECK FOR INTERMITTENT PROBLEMS)
NG
Turn the ignition switch to ON.
Start the engine.
| Result | Proceed to |
|---|---|
| Engine starts | A |
| Engine does not start* | B |
*: The GTS cannot communicate with the ECM.
A
B
Disconnect the combination meter assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-11 (CHK) - A62-27 (W) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG