Home › Engine / Hybrid System › 2WW ENGINE CONTROL › ECM › from 2015.10
RM3090E _51 Engine / Hybrid System _044372 2WW ENGINE CONTROL _0208482 ECM A

2WW ENGINE CONTROL  ECM  INSTALLATION  


PROCEDURE

Hide 89661A 1.INSTALL ECM

a.

Install the No. 2 ECM bracket to the ECM with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


b.

Install the No. 1 ECM bracket to the ECM with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


c.

Install the ECM with the 3 bolts.

Torque:
6.5 N*m (66 kgf*cm, 58 in.*lbf)

NOTICE:

Avoid physical shock to the ECM.



d.

Attach the claw and connect the relay.


e.

Connect the 2 ECM connectors and lower the 2 levers.

NOTICE:
·

When connecting the ECM connectors, make sure that the connecting parts of the ECM connectors are free of dirt, water or other foreign matter.

·

Be sure to securely connect the ECM connectors.




Hide 2.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

a.

Install the air cleaner case sub-assembly with the 3 bolts.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


Hide 17801 3.INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 4.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

a.

Install the air cleaner cap sub-assembly to the air cleaner hose assembly and tighten the hose clamp.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


b.

Attach the 2 clamps.


c.

Connect the mass air flow meter connector and attach the wire harness clamp.


Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 7.PERFORM INITIALIZATION