Home › Power Source / Network › 3ZR-FE BATTERY / CHARGING › GENERATOR(for 130 A Type) › from 2015.10
RM3090E _57 Power Source / Network _008412 3ZR-FE BATTERY / CHARGING _0208765 GENERATOR(for 130 A Type) A

3ZR-FE BATTERY / CHARGING  GENERATOR(for 130 A Type)  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Install the wire harness clamp bracket with the bolt.

Torque:
7.7 N*m (79 kgf*cm, 68 in.*lbf)


b.
A296609

Temporarily install the generator with the bolt.


c.
A296608

Temporarily install the adjusting bar with the 2 bolts.


d.

Install the wire harness to terminal B with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


e.

Install the terminal cap.


f.

Connect the connector and attach the wire harness clamp.


g.
A297357

Tighten the bolt.

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 11212 6.INSTALL NO. 2 CYLINDER HEAD COVER

Hide 51443 7.INSTALL REAR ENGINE UNDER COVER RH

Hide 51441 8.INSTALL NO. 1 ENGINE UNDER COVER