Home › Engine / Hybrid System › STOP AND START › STOP AND START SYSTEM(for 3ZR-FAE) › from 2015.10
RM3090E _51 Engine / Hybrid System _009049 STOP AND START _0166176 STOP AND START SYSTEM(for 3ZR-FAE) J

STOP AND START  STOP AND START SYSTEM(for 3ZR-FAE)  Stop and Start System does not Operate (Battery Condition)  


DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.

HINT:
Data List items
Oper Permission (Battery) Oper Permission (Start Min Volt 1) Oper Permission (Start Min Volt 2) Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4) Oper Permission (Battery Current) Oper Permission (Integrated Current) Oper Prohibition (Jump Start)
Battery Type State of BBC Alternator Status Idling Stop Rate
Total Idling Stop Rate Battery Fluid Temperature Ambient Temp Sensor Status of Battery Charge Control
Battery Temp (Start) Min Voltage(Cranking) Min Volt(After Cranking) Battery Current
Integrated Current Hood Courtesy Switch Oper Prohibition (Manual Start) -


NOTICE:

If the Data List item Oper Permission (Battery) is "NG" even after correcting a certain problem using the diagnostic troubleshooting procedures, the problem may be due to the battery charge amount being temporarily low or the battery may be deteriorated. However, there may be multiple overlapping conditions which are causing system operation to be prohibited, so make sure to always confirm all the diagnostic troubleshooting procedures.


PROCEDURE

1.CONFIRM MODEL
a.

Check whether a multi-information display is equipped.


Result:
Result Proceed to
Equipped A
Not equipped B



A

2.CHECK MULTI-INFORMATION DISPLAY

B

4.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
2.CHECK MULTI-INFORMATION DISPLAY
a.

Check whether the multi-information display displayed that the specified battery is not equipped.

HINT:

The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified battery when stop and start control is operated.



Result:
Result Proceed to
No display A
Displayed in past B



A

3.CHECK DTC OUTPUT

B

15.CHECK BATTERY SETTINGS AND EQUIPPED BATTERY
3.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Trouble Codes.


e.

Read the DTCs.

Powertrain > Stop and Start > Trouble Codes
50001 227
Result:
Result Proceed to
DTCs are not output A
DTCs are output B




A

4.READ VALUE USING GTS (OPER PERMISSION (BATTERY))

B

4.READ VALUE USING GTS (OPER PERMISSION (BATTERY))
HINT:

Check whether stop and start control was prohibited based on the battery conditions or other conditions.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Type Range Diagnostic Note
Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed -
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
50003 227 120
Result:
Result Proceed to
NG is displayed A
OK is displayed B




A

5.READ VALUE USING GTS (BATTERY TYPE)

B

END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

5.READ VALUE USING GTS (BATTERY TYPE)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.


e.

Check the "Battery Type" Data List Item.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 227 421

f.

Check whether the battery is specified or not specified.


Result:
Data List Battery Type Display Proceed to
Specified A
Other B



A

6.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

B

15.CHECK BATTERY SETTINGS AND EQUIPPED BATTERY
6.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))
HINT:

Check whether stop and start control was prohibited based on the jump start battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to ON When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Jump Start)
50003 227 128
Result:
Result Proceed to
Permit is displayed (for CVT) A
Permit is displayed (for Manual Transaxle) B
Prohibit is displayed C


HINT:
·

A jump start is determined if the engine is started with the engine hood open.

·

After turning the ignition switch off and waiting approximately 30 seconds, a jump start is determined to have not occurred if the engine is started with the engine hood closed.





A

7.READ VALUE USING GTS (STATE OF BBC)

B

17.READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))

C

20.READ VALUE USING GTS (HOOD COURTESY SWITCH)
7.READ VALUE USING GTS (STATE OF BBC)
HINT:

Check the operation of the backup boost converter.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
State of BBC Backup boost converter status Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status Normal: Backup boost converter operating normally
·

Cycle Err:

·

Abnormal output voltage cycle is detected


·

Overvol:

·

When the ignition switch is ON:

1.

Overvoltage is detected at the control IC power source within the backup boost converter

2.

Overheating is detected at the control IC power source within the backup boost converter



·

When boosting:

1.

Malfunction is detected in the feedback circuit in the backup boost converter

2.

Too high or low output voltage



·

Overload:

·

Overcurrent is detected.


·

Low Vol:

·

A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.


·

Duty Err:

·

Abnormal duty ratio is detected



Powertrain > Stop and Start > Data List
Tester Display
State of BBC
50003 227 69
Result:
Result Proceed to
Normal is displayed A
Normal is not displayed B




A

8.READ VALUE USING GTS (ALTERNATOR STATUS)

B

8.READ VALUE USING GTS (ALTERNATOR STATUS)
HINT:

Check the power generation status of the generator.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Alternator Status Generator power generation status Normal / Abnormal Normal: Generator operation normal -
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
50003 227 298
Result:
Result Proceed to
Normal is displayed A
Abnormal is displayed B




A

9.READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)

B

9.READ VALUE USING GTS (IDLING STOP RATE, TOTAL IDLING STOP RATE)
HINT:

Check the idling stop rate.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate and Total Idling Stop Rate.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time Min.: 0%
Max.: 100%
- -
Total Idling Stop Rate Rate of total idling stop time Min.: 0%
Max.: 100%
- -
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
50003 227 176,272
Result:
Result Proceed to
Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower A
Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher B




A

10.READ VALUE USING GTS (BATTERY FLUID TEMPERATURE, AMBIENT TEMP SENSOR)

B

END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE 50% OR MORE OR TOTAL IDLING STOP RATE 40% OR MORE)
HINT:
·

If Idling Stop Rate is higher than 50% or Total Idling Stop Rate is higher than 40%, leave the vehicle with the engine running until Idling Stop Rate drops below 50% or Total Idling Stop Rate drops below 40%.

·

Prohibition according to the Idling Stop Rate is used to limit a high frequency of stop and start operations in order to ensure the lifespan of the battery. Operation may be prohibited again due to the customer usage conditions.




10.READ VALUE USING GTS (BATTERY FLUID TEMPERATURE, AMBIENT TEMP SENSOR)
HINT:

Check the battery temperature.


a.

Enter the following menus: Powertrain / Stop and Start / Data List.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Battery fluid temperature Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up -
Ambient Temp Sensor Ambient temperature Min.: -80°C (-112°F)
Max.: 79.9°C (175.8°F)
Close to ambient temperature -
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
50003 227 302,63
Result:
Proceed to Proceed to
Both Battery Fluid Temperature and Ambient Temp Sensor are suitable temperature
(Battery Fluid Temperature: -10°C (14°F) to 70°C (158°F), Ambient Temp Sensor: -5°C (23°F) or higher)
A
Battery Fluid Temperature or Ambient Temp Sensor is not suitable temperature
(Battery Fluid Temperature: -15°C (5°F) or less or 75°C (167°F) or higher, Ambient Temp Sensor: -6°C (21.2°F) or less)
B


HINT:

The Battery Fluid Temperature hysteresis is 5°C (41°F) and the Ambient Temp Sensor hysteresis is 1°C (33.8°F).




A

11.READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)

B

END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE)
HINT:
·

If Battery Fluid Temperature is not a suitable temperature, leave the vehicle at ambient temperature to allow Battery Fluid Temperature to return to a suitable temperature.

·

Operation is prohibited due to the battery temperature to ensure engine startability and protect the battery. This occurs due to the usage environment.




11.READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)
HINT:

Check whether stop and start control was prohibited based on the battery charge control mode.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Status of Battery Charge Control Battery charge control status Charge Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High/Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode - -
Powertrain > Stop and Start > Data List
Tester Display
Status of Battery Charge Control
50003 227 273
Result:
Result Proceed to
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed A
"Refresh Charge Mode" is displayed B
"Abnormal Mode" is displayed C
"Battery Condition Judgment Mode" is displayed D




A

12.READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))

B

END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)
HINT:

Let the vehicle idle with the battery temperature at 11°C (51.8°F) or higher for 30 to 60 minutes to complete the refresh charge. (The refresh charge is complete when Status of Battery Charge Control changes from "Refresh Charge Mode".)



C

D

END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE)

12.READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))
HINT:

Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Start Min Volt 1) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
50003 227 124,123,122,121
Result:
Result Proceed to
OK is displayed for 2 or more items A
OK is displayed for 1 item or none B


i.

The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Same as temperature around battery at engine start (after engine start) -
Min Voltage(Cranking) Minimum voltage when cranking engine Min.: 0 V
Max.: 327.67 V
6 to 11 V Lowest battery voltage measured in a 5 second period after the starter starts operating.
Min Volt(After Cranking) Minimum voltage when starter begins operation Min.: 0 V
Max.: 327.67 V
6 to 11 V Minimum battery voltage while starter driving
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Temp (Start)
Min Voltage(Cranking)
Min Volt(After Cranking)
Battery Type
50003 227 153,67,210,421
Permission Criteria (Specified Battery) for CVT:
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 8.14 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 8.14 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 7.6 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 7.6 V or higher Higher than 0°C (32°F)

Permission Criteria (Specified Battery) for Manual Transaxle:
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 6.5 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 6.5 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 6.5 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 6.5 V or higher Higher than 0°C (32°F)


Permission Criteria (Non-specified Battery):
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 8.92 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 8.92 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 8.92 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 8.92 V or higher Higher than 0°C (32°F)





A

13.READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))

B

19.CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE
13.READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))
HINT:

Check whether stop and start control was prohibited based on the integrated current value battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value condition NG / OK OK: Integrated current value more than specified The status depends on the value of "Integrated Current", and the OK/NG threshold differs according to the battery temperature.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Integrated Current)
50003 227 126
Result:
Result Proceed to
OK is displayed A
NG is displayed B




A

14.READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))

B

18.READ VALUE USING GTS (INTEGRATED CURRENT)
14.READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))
HINT:

Check whether stop and start control was prohibited based on the battery discharge current battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Permission (Battery Current) Permission of stop and start control based on battery current NG / OK OK: Battery discharge current is -125 A or higher Engine stop and start ECU calculated value
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery Current)
50003 227 125
Result:
Result Proceed to
OK is displayed A
NG is displayed B


HINT:

The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.


Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Current Battery current Min.: -125 A
Max.: 124.99 A
- -
Powertrain > Stop and Start > Data List
Tester Display
Battery Current
50003 227 60
Permission Criteria:
Tester Display Battery Current
Oper Permission (Battery Current) -125 A or higher




A

CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)

Refer to Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION


B

END (TURN ELECTRICAL LOAD OFF AS MUCH AS POSSIBLE)

15.CHECK BATTERY SETTINGS AND EQUIPPED BATTERY
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.


e.

Check the "Battery Type" Data List Item.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 227 421

f.

Check whether the battery is specified or not specified.


Result:
Data List Battery Type Display Equipped Battery Proceed to
Other Specified battery A
Other Non-specified battery B



A

16.SWITCH BATTERY TYPE

B

EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT BATTERY MALFUNCTION WHEN A NON-SPECIFIED BATTERY IS USED
HINT:

When switching to a specified battery, Battery Type may not immediately switch to "Specified". To immediately switch it to "Specified", perform Switch Battery Type.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION



16.SWITCH BATTERY TYPE
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.

Powertrain > Engine and ECT > Utility
Tester Display
Switch Battery Type
50005 234 4377

e.

Perform Switch Battery Type under Utility and set the Specified battery.


f.

Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.


g.

Check that the "Battery Type" Data List item is set to "Specified".

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Type Set battery type Specified / Other Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
50003 227 421

Result:
Proceed to
NEXT



NEXT

END

17.READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))
HINT:

Check whether the stop and start control was prohibited based on the manual start battery condition.


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).


b.

Check the following items on the GTS display.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Prohibition (Manual Start) Prohibition of stop and start control based on the manual start conditions Permit / Prohibit Prohibit: During manual start When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Conditions for Manual Start:
·

Clutch start switch OFF or vehicle speed signal input

·

Neutral position sensor (neutral position switch) OFF

·

Starter signal OFF


Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Manual Start)
50003 227 129

Result:
Result Proceed to
Permit is displayed A
Prohibit is displayed B



A

7.READ VALUE USING GTS (STATE OF BBC)

B

END (STOP AND START CONTROL PROHIBITED DUE TO MANUAL START OPERATION)

18.READ VALUE USING GTS (INTEGRATED CURRENT)
HINT:

Judge the battery condition based on the integrated current value.


a.

Start the engine and allow it to idle.


b.

Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.


c.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Integrated Current Battery integrated current Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge/discharge conditions) -
Powertrain > Stop and Start > Data List
Tester Display
Integrated Current
50003 227 65
i.

Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Fluid Temperature Battery fluid temperature Min.: -40°C (-40°F)
Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up -
Battery Current Battery current Min.: -125 A
Max.: 124.99 A
- -
Integrated Current Battery integrated current Min.: -268434.45 A-sec
Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge/discharge conditions) -
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Battery Current
Integrated Current
50003 227 302,60,65
Standard Integrated Current Value:
Status of Battery Charge Control Battery Fluid Temperature Integrated Current Proceed to
Charge Control Coordination Mode or Stop and Start Standalone Mode -15°C (5°F) or higher or below 75°C (167°F) Below -13478 A-sec A
Low Temperature Mode Between 3°C (37.4°F) and under 11°C (51.8°F) Below -6048 A-sec
Low Temperature Mode Between -1°C (30.2°F) and under 3°C (37.4°F) Below -3974 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode -15°C (5°F) or higher or below 75°C (167°F) Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode Below -15°C (5°F) or 75°C (167°F) or higher - B


Cause and Action to be Taken:
Result Cause Action to be Taken
A Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery Check the battery condition and recharge or replace the battery
B Integrated current value is limited for stop and start control due to battery temperature (too high/low) Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.


·

Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).

*: Use the GTS to perform Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION

HINT:

If the Data List item "Integrated Current" is 0 or higher, it is not necessary to perform initialization.


·

When the battery state sensor assembly current value is normal, recharge or replace the battery

·

When the electrical load is large, a large amount of electrical discharge occurs. As a result, the integrated current value (battery charge amount) tends to drop causing operation to be prohibited.




Result:
Proceed to
NEXT



NEXT

CHARGE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)

Refer to Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION


19.CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE
a.

Check the battery.

Click herePower Source / Network>3ZR-FAE BATTERY / CHARGING>CHARGING SYSTEM>ON-VEHICLE INSPECTION

HINT:
·

Charge or replace the battery according to the check result.

·

When the cable is disconnected from the battery terminal or the charging control system is checked (ECM connector is disconnected), do not perform this procedure, as there is a high possibility that the system may enter refresh charge mode and operation may be prohibited.





c.

Start the engine.


d.

Enter the following menus: Powertrain / Stop and Start / Data List.


e.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Current Battery current Min.: -125 A
Max.: 124.99 A
- -
Powertrain > Stop and Start > Data List
Tester Display
Battery Current
50003 227 60

f.

While idling, illuminate the headlights (Lo).

HINT:

The headlights (Lo) are illuminated so that charging control is prohibited, which sets the voltage to a fixed value.



g.

Charge the battery until the Data List item Battery Current becomes 5 A or less for approximately 5 minutes.

HINT:

The Data List item Battery Current decreases when the battery is charged. If the battery is charged for 5 minutes after Battery Current drops to 5 A or less, it can be determined that the battery issufficiently charged.



h.

Turn off the headlights.


i.

Turn the ignition switch off and wait for 30 seconds or more.


j.

Start the engine and check the following Data List items.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Min Voltage(Cranking) Minimum voltage when cranking engine Min.: 0 V
Max.: 327.67 V
6 to 11 V Lowest battery voltage measured after the starter starts operating.
Min Volt(After Cranking) Minimum voltage when starter begins operation Min.: 0 V
Max.: 327.67 V
6 to 11 V Minimum battery voltage while starter operating
Oper Permission (Start Min Volt 1) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2) Permission of stop and start control based on minimum voltage during starting when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is 0°C (32°F) or less NG / OK OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4) Permission of stop and start control based on minimum voltage after cranking when battery fluid temperature is more than 0°C (32°F) NG / OK OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Powertrain > Stop and Start > Data List
Tester Display
Min Voltage(Cranking)
Min Volt(After Cranking)
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
50003 227 67,210,124,123,122,121
Permission Criteria (Specified Battery) for CVT:
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 8.14 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 8.14 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 7.6 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 7.6 V or higher Higher than 0°C (32°F)

Permission Criteria (Specified Battery) for Manual Transaxle:
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 6.5 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 6.5 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 6.5 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 6.5 V or higher Higher than 0°C (32°F)


Permission Criteria (Non-specified Battery):
Tester Display Min Voltage (Cranking) Min Volt (After Cranking) Battery Temp (Start)
Oper Permission (Start Min Volt 1) 8.92 V or higher - 0°C (32°F) or less
Oper Permission (Start Min Volt 2) 8.92 V or higher - Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3) - 8.92 V or higher 0°C (32°F) or less
Oper Permission (Start Min Volt 4) - 8.92 V or higher Higher than 0°C (32°F)



k.

Replace the battery in the following situations.

·

Oper Permission (Start Min Volt (1, 2, 3, 4)) are not OK

·

Oper Permission (Start Min Volt (1, 2, 3, 4)) are OK, but Min Voltage (Cranking) and Min Volt (After Cranking) values are close to permission criteria



Result:
Proceed to
NEXT



NEXT

INITIALIZE INTEGRATED CURRENT VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)

Refer to Integrated Current Value Initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM(for 3ZR-FAE)>REGISTRATION


20.READ VALUE USING GTS (HOOD COURTESY SWITCH)
HINT:

Check the engine hood courtesy switch (hood lock assembly).


a.

Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.


b.

According to the display on the GTS, read the Data List.

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Hood Courtesy Switch Hood courtesy switch signal ON / OFF ON: Engine hood closed
OFF: Engine hood opened
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
50003 227 8
Result:
Result Proceed to
When engine hood condition changes from open to closed, Data List switches from OFF to ON A
When engine hood condition changes from open to closed, Data List remains OFF B


HINT:

If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.




A

21.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

B

GO TO ENGINE HOOD COURTESY SWITCH CIRCUIT (OPERATION PROHIBITED AS ENGINE HOOD STATE DOES NOT CHANGE TO CLOSE)

21.READ VALUE USING GTS (OPER PROHIBITION (JUMP START))
a.

Check that the engine hood is closed.


b.

Turn the ignition switch off and wait for 30 seconds or more.


c.

Turn the ignition switch to ON.


d.

Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).


e.

Check that the Data List item "Oper Prohibition (Jump Start)" displays "Permit".

Powertrain > Stop and Start > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start condition Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to ON When Prohibit is displayed, stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Jump Start)
50003 227 128
Result:
Proceed to
NEXT


HINT:

Stop and start control may be prohibited if the engine was started with the engine hood open.




NEXT

END