Home › Drivetrain › K114F MULTIDRIVE / CVT › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › from 2015.10
RM3090E _52 Drivetrain _036009 K114F MULTIDRIVE / CVT _0166287 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM C

K114F MULTIDRIVE / CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  P282B  Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS)  


DESCRIPTION

According to current control by the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.

C267073C01
5.094,0.646 4.875,0.188 4.875,0.188 4.729,0.188 true 4.75,0.885 4.625,1.083 4.625,1.083 4.198,1.083 true 5.885,0.396 5.26,1.313 5.26,1.313 5.896,0.969 true 1.969,1.385 2.26,1.615 0.292,0.229 10 false *b 1.177,0.542 1.385,0.792 0.208,0.25 10 false *a 4.583,0.104 4.781,0.313 0.198,0.208 10 false *1 4.01,1 4.229,1.188 0.219,0.188 10 false *2 5.073,1.24 5.292,1.479 0.219,0.24 10 false *3
*1 Spool Valve *2 Sleeve
*3 Solenoid Coil - -
*a Hydraulic Pressure *b Current Flow to Solenoid


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P282B Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS) 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.

The vehicle is being driven.

2.

An open or short circuit in the shift solenoid valve SLS circuit is detected.

3.

1 second or more

4.

1-trip detection logic


·

Harness or connector

·

Continuously variable transaxle assembly (Shift solenoid valve SLS)

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. If there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

C262369E76
0.896,1.979 2.542,2.167 1.646,0.188 10 false Shift Solenoid Valve SLS 1.094,2.823 3.75,3.219 2.656,0.396 10 false Continuously Variable Transaxle Assembly (Transmission Wire) 1.083,2.656 1.563,2.865 0.479,0.208 10 false B105 5.698,2.729 6.146,2.906 0.448,0.177 10 false B93 5.573,1.677 6,1.865 0.427,0.188 10 false SLS- 5.573,0.896 6.135,1.104 0.563,0.208 10 false SLS+ 5.302,1.542 5.635,1.844 0.333,0.302 10 false 44 5.292,0.771 5.781,1.167 0.49,0.396 10 false 45 4.365,1.542 4.542,1.719 0.177,0.177 10 false 8 4.365,0.771 4.719,1.073 0.354,0.302 10 false 2 5.708,2.906 6.188,3.156 0.479,0.25 10 false ECM 3.938,1.552 4.281,1.729 0.344,0.177 10 false SLS- 3.906,0.771 4.49,1 0.583,0.229 10 false SLS+

CAUTION / NOTICE / HINT

NOTICE:
·

Perform initialization when parts related to the continuously variable transaxle are replaced.

Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION

·

Check that no DTCs are stored after performing initialization.

Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>DTC CHECK / CLEAR



PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)
a.
C298188C12
2.813,0.563 2.177,0.927 true 2.833,1.552 2.177,1.271 true 2.865,0.49 3.323,0.688 0.458,0.198 10 false SLS+ 2.906,1.51 3.365,1.708 0.458,0.198 10 false SLS- 0.104,0.104 0.563,0.302 0.458,0.198 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (SLS+) - 8 (SLS-) 20°C (68°F) 5.0 to 5.6 Ω
2 (SLS+) - Body ground and other terminals Always 10 kΩ or higher
8 (SLS-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

4.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C326700C01
1.427,0.198 1.813,0.427 0.385,0.229 0.948,1.677 1.25,0.948 true 1.677,1.698 1.323,0.948 true 0.125,0.083 0.438,0.24 0.313,0.156 10 false *a 0.635,1.75 1.396,1.969 0.76,0.219 10 false 44 (SLS-) 1.5,1.771 2.26,1.99 0.76,0.219 10 false 45 (SLS+) 1.51,0.24 1.969,0.438 0.458,0.198 10 false B93
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B93-45 (SLS+) - B93-44 (SLS-) 20°C (68°F) 5.0 to 5.6 Ω
B93-45 (SLS+) - Body ground and other terminals Always 10 kΩ or higher
B93-44 (SLS-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)

3.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

4.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
a.

Replace the continuously variable transaxle assembly.

Click hereDrivetrain>K114F MULTIDRIVE / CVT>CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY>REMOVAL


Result:
Proceed to
NEXT



NEXT