This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa [1.8 kgf/cm2, 26 psi] or less) or extremely high (3025 kPa [30.8 kgf/cm2, 439 psi] or more). The air conditioner pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Pressure Sensor Circuit | ·
Open or short in air conditioner pressure sensor circuit ·
Refrigerant pressure on high pressure side is extremely low (176 kPa [1.8 kgf/cm2, 26 psi] or less) or extremely high (3025 kPa [30.8 kgf/cm2, 439 psi] or more) |
·
Air conditioner pressure sensor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Cooler expansion valve (blocked, stuck) ·
Condenser assembly (blocked, deterioration of cooling capacity due to dirt) ·
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed) ·
Cooling fan system (condenser assembly cannot be cooled down) ·
Air conditioning system (leaks, blocked) |
- |
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B1423 first.
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A34-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A34-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Remove the air conditioning amplifier assembly with the connector still connected.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G80-7 (PRE) - Body ground | Ignition switch ON
A/C switch off |
0.74 to 4.62 V |
If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage when the following conditions are satisfied.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Engine speed | 2000 rpm |
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G80-7 (PRE) - Body ground | Ignition switch ON
A/C switch on |
0.74 to 4.62 V |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Disconnect the G80 air conditioning amplifier assembly connector.
Disconnect the A34 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G80-24 (S5-3) - A34-3 (+) | Always | Below 1 Ω |
| G80-24 (S5-3) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G80 air conditioning amplifier assembly connector.
Disconnect the A34 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G80-5 (SG-2) - A34-1 (-) | Always | Below 1 Ω |
| G80-5 (SG-2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A34 air conditioner pressure sensor connector.
Disconnect the G80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A34-2 (PR) - G80-7 (PRE) | Always | Below 1 Ω |
| A34-2 (PR) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Install a manifold gauge set.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
Evacuate the air conditioning system and check that vacuum can be maintained in it.
If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.
Vacuum can be maintained in the air conditioning system.
| Result |
|---|
| OK |
| NG |
OK
NG
Use a refrigerant recovery unit to recover refrigerant.
Evacuate the air conditioning system.
Add an appropriate amount of refrigerant.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs when the following conditions are satisfied.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Engine speed | 2000 rpm |
If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
DTC B1423 is not output.
| Proceed to |
|---|
| OK |
| NG |
If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.
OK
NG
Identify the area where refrigerant leaks from.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT
Repair the identified area of the air conditioning system.
Evacuate the air conditioning system.
| Proceed to |
|---|
| NEXT |
NEXT
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Install a manifold gauge set.
Connect the A34 air conditioner pressure sensor connector.
Turn the ignition switch to ON.
Turn the A/C switch on.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G80-7 (PRE) - G80-5 (SG-2) | Engine running
Air conditioning system operating Refrigerant pressure: Normal pressure (less than 3025 kPa [30.9 kgf/cm2, 439 psi] and more than 176 kPa [1.8 kgf/cm2, 25 psi]) |
0.74 to 4.62 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check that the cooling fan(s) operates normally.
for 2AD-FHV (w/ Towing Package):Engine / Hybrid System>2AD-FHV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>ON-VEHICLE INSPECTION
for 2AD-FHV (w/o Towing Package):Engine / Hybrid System>2AD-FHV COOLING>COOLING FAN SYSTEM(w/o Towing Package)>ON-VEHICLE INSPECTION
for 2AD-FTV (w/ Towing Package):Engine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>ON-VEHICLE INSPECTION
for 2AD-FTV (w/o Towing Package):Engine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/o Towing Package)>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for 2AD-FHV (w/ Towing Package):Engine / Hybrid System>2AD-FHV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>PROBLEM SYMPTOMS TABLE
for 2AD-FHV (w/o Towing Package):Engine / Hybrid System>2AD-FHV COOLING>COOLING FAN SYSTEM(w/o Towing Package)>PROBLEM SYMPTOMS TABLE
for 2AD-FTV (w/ Towing Package):Engine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>PROBLEM SYMPTOMS TABLE
for 2AD-FTV (w/o Towing Package):Engine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/o Towing Package)>PROBLEM SYMPTOMS TABLE
Use a refrigerant recovery unit to recover refrigerant.
Evacuate the air conditioning system.
Add an appropriate amount of refrigerant.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs when the following conditions are satisfied.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Engine speed | 2000 rpm |
If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs. If the DTC is not output after this work, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.
DTC B1423 is not output.
| Proceed to |
|---|
| OK |
| NG |
OK
for: 3ZR-FE, 3ZR-FAE, 2AR-FE:Vehicle Interior>HEATING / AIR CONDITIONING>CONDENSER(for 3ZR-FE, 3ZR-FAE, 2AR-FE)>REMOVAL
NG
Replace the cooler expansion valve with a new one.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL
Replace the cooler expansion valve with a new one because the cooler expansion valve is either stuck or clogged.
| Proceed to |
|---|
| NEXT |
NEXT
Use a refrigerant recovery unit to recover refrigerant.
Evacuate the air conditioning system.
Add an appropriate amount of refrigerant.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs when the following conditions are satisfied.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Engine speed | 2000 rpm |
If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to operate the air conditioning system for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant pressure is not normal after replacing the cooler expansion valve with a new or known good one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the cooler condenser assembly or pipes.
DTC B1423 is not output.
| Proceed to |
|---|
| OK |
| NG |
OK
NG