When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
Inspect the fuses for circuits related to this system before performing the following procedure.
w/ Entry and Start System:
If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Security Horn | Security horn assembly | ON or OFF | - |
| Tester Display |
|---|
| Security Horn |
The security horn assembly sounds and stops correctly when operated through the GTS.
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
NG
Remove the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>REMOVAL
Inspect the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security warning relay (S-HORN).
Measure the resistance according to the value(s) in the table below
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Security warning relay (S-HORN) terminal 3 - Security warning relay (S-HORN) terminal 5 | Auxiliary battery voltage is applied between security warning relay (S-HORN) terminals 2 - 1 | Below 1 Ω |
| Security warning relay (S-HORN) terminal 3 - Security warning relay (S-HORN) terminal 5 | Auxiliary battery voltage is not applied between security warning relay (S-HORN) terminals 2 - 1 | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the main body ECU (multiplex network body ECU).
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Connect the instrument panel junction block assembly connectors.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the security warning relay (S-HORN).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Security warning relay (S-HORN) terminal 2 - A-29 (SH) | Always | Below 1 Ω |
| Security warning relay (S-HORN) terminal 2 or A-29 (SH) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Security Warning Relay [S-HORN]) |
Remove the security warning relay (S-HORN).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Security warning relay (S-HORN) terminal 1 - Body ground | Ignition switch off | 11 to 14 V |
| Security warning relay (S-HORN) terminal 5 - Body ground | Ignition switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security warning relay (S-HORN).
Disconnect the A16 security horn assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Security warning relay (S-HORN) terminal 3 - A16-1 | Always | Below 1 Ω |
| Security warning relay (S-HORN) terminal 3 or A16-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
NG
Disconnect the 4A instrument panel junction block assembly connector.
Remove the security warning relay (S-HORN).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Security warning relay (S-HORN) terminal 2 - 4A-20 | Always | Below 1 Ω |
| Security warning relay (S-HORN) terminal 2 or 4A-20 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
NG