Use the same procedure as for the LHD and RHD vehicles.
The procedure listed below is for the LHD vehicles.
1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>REPLACEMENT
for HFO-1234yf (R1234yf):
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFO-1234yf(R1234yf))>REPLACEMENT
G92A0A
2.DISCONNECT INVERTER RESERVE TANK ASSEMBLY
Remove the 2 bolts.
| *a | Pin |
|
Grommet |
|
Movement Direction |
Pull out the pin of the grommet and move the inverter reserve tank assembly as shown in the illustration.
88718L
3.REMOVE PIPING CLAMP (for Suction Hose Sub-assembly Side)
Press the suction hose sub-assembly to the suction pipe sub-assembly, and then release the piping clamp lock.
Do not apply excessive force to the suction hose sub-assembly and suction pipe sub-assembly.
| *1 | Suction Hose Sub-assembly | *2 | Suction Pipe Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Press In | - | - |
While releasing the piping clamp lock, use pliers or another tool to pinch near the rear end of the piping clamp, and then disconnect the suction hose sub-assembly as you buckle it.
If any foreign matter is attached to the connecting parts, brush it off or use compressed air to remove it before disconnecting the parts.
Make sure that fragments of the piping clamp do not enter the piping.
When the piping clamp is buckled, cracks form. Therefore, make sure to replace it with a new one.
Remove any foreign matter from the connecting parts of the suction hose sub-assembly and suction pipe sub-assembly.
| *1 | Suction Hose Sub-assembly | *2 | Suction Pipe Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Buckle | *b | Pull Out |
Remove the 2 O-rings from the suction hose sub-assembly.
Seal the openings of the disconnected parts with vinyl tape to prevent entry of moisture and foreign matter.
Remove the piping clamp.
88718N
4.REMOVE PIPING CLAMP (for Air Conditioning Tube and Accessory Assembly Side)