If the power switch is pressed with the electrical key transmitter sub-assembly in the cabin, the certification ECU (smart key ECU assembly) receives a signal and changes the power source mode.
| Problem Symptom | Data List and Active Test |
|---|---|
| Power source mode does not change to on (IG) but does change to on (ACC) | Power Source Control
·
Power Supply Condition ·
IG Relay Monitor (Inside) ·
IG Relay Monitor (Outside) |
When using the GTS with the power switch off, connect the GTS to the DLC3 and turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and the vehicle begins. Then select Model Code "KEY REGIST" under manual mode and enter the following menus: Body Electrical / Entry&Start. While using the GTS, periodically turn a courtesy light switch on and off at intervals of 1.5 seconds or less to maintain communication between the GTS and the vehicle.
Make sure that no DTCs are output. If any DTCs are output, proceed to Diagnostic Trouble Code Chart.
If the entry and start system (for Start Function) has been canceled, enable the system before performing troubleshooting.
Inspect the fuses of circuits related to this system before performing the following procedure.
Before replacing the certification ECU (smart key ECU assembly), refer to the Service Bulletin.
After completing repairs, confirm that the problem does not recur.
After repair, confirm that no DTCs are output by performing "DTC Output Confirmation Operation".
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Entry&Start, Power Source Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| Entry and start system (for Start Function) DTCs are output | B |
A
B
| *a | Component with harness connected
(Certification ECU (Smart Key ECU Assembly)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G54-17 (IG1D) - Body ground | Power switch on (ACC) → Power switch on (IG) | 1 V or less → 9 V or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G54 certification ECU (smart key ECU assembly) connector.
Disconnect the 4A, 4F, 4K and 4L instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G54-17 (IG1D) - 4A-17 | Always | Below 1 Ω |
| 4F-13 - Body ground | Always | Below 1 Ω |
| G54-17 (IG1D) or 4A-17 - Other terminals and body ground | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4K-1 - Body ground | Power switch off | 11 to 14 V |
| 4L-1 - Body ground | Power switch off | 11 to 14 V |
Reconnect the G54 certification ECU (smart key ECU assembly) connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Remove the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4A-17 - 4F-13 | Always | Below 1 Ω |
Connect a positive (+) lead from the auxiliary battery to terminal 4A-17.
Connect a negative (-) lead from the auxiliary battery to terminal 4D-3.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4K-1 - 4D-31 | Always | Below 1 Ω |
| 4K-1 - 4F-2 | Always | Below 1 Ω |
| 4L-1 - 4F-15 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Disconnect the 4F instrument panel junction block assembly connector.
Remove the IG2 NO.1 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4F-13 - IG2 NO.1 relay installation terminal 1 | Always | Below 1 Ω |
| IG2 NO.1 relay installation terminal 2 - Body ground | Always | Below 1 Ω |
| 4F-13 or IG2 NO.1 relay installation terminal 1 - Other terminals and body ground | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IG2 NO.1 relay installation terminal 5 - Body ground | Power switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | IG2 NO. 1 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG