The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed, installed or replaced during the mobilephone battery removal/installation are shown below.
1. PRECAUTION (for eCall)
2. PRECAUTION (for ERA-GLONASS)
86740
3.REMOVE TELEPHONE TRANSCEIVER ASSEMBLY
86725
4.REMOVE MOBILEPHONE BATTERY (for eCall)
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
Detach the claw and guide and remove the transceiver cover as shown in the illustration.
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
Disconnect the connector.
Detach the guide and remove the mobilephone battery as shown in the illustration.
86725
5.REMOVE MOBILEPHONE BATTERY (for ERA-GLONASS)
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
Loosen the 2 screws.
The 2 screws cannot be removed because they are integrated into the battery cover sub-assembly.
Detach the claw and guide as shown in the illustration to remove the battery cover sub-assembly.
Lift the battery, disconnect the connector and remove the battery as shown in the illustration.
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |