DTC P0327 Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor) |
DTC P0328 Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor) |
DTC P0332 Knock Sensor 2 Circuit Low Input (Bank 2) |
DTC P0333 Knock Sensor 2 Circuit High Input (Bank 2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0327 P0332 | Output voltage of knock sensor less than 0.5 V (1 trip detection logic) |
|
| P0328 P0333 | Output voltage of knock sensor more than 4.5 V (1 trip detection logic) |
|

| Item | Content |
| Terminal | KNK1 - EKNK KNK2 - EKN2 |
| Equipment Setting | 1 V/DIV. 1 msec./DIV. |
| Condition | Keep engine speed at 4000 rpm with warm engine |
| Related DTCs | P0327: Knock sensor (for bank 1) range check (Low voltage) P0328: Knock sensor (for bank 1) range check (High voltage) P0332: Knock sensor (for bank 2) range check (Low voltage) P0333: Knock sensor (for bank 2) range check (High voltage) |
| Required Sensors/Components (Main) | Knock sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or more |
| Time after engine start | 5 seconds or more |
| Knock sensor voltage | Less than 0.5 V |
| Knock sensor voltage | More than 4.5 V |

| 1.READ OUTPUT DTC (CHECK KNOCK SENSOR CIRCUIT) |
![]() |
Disconnect the ED2 connector.
Using lead wires, connect the connectors as follows:
| Male Connector - Female Connector |
| Terminal 10 - Terminal 4 |
| Terminal 9 - Terminal 5 |
| Terminal 4 - Terminal 10 |
| Terminal 5 - Terminal 9 |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream ON.
Clear DTCs (Click here).
Warm up the engine.
Run the engine at 3000 rpm for 10 seconds or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| DTC is same as when vehicle brought in (for example, P0327 and P0328 are output again, or P0332 and P0333 are output again) | A |
| DTC is different from when vehicle brought in (for example, P0327 and P0328 are output at first, but then P0332 and P0333 are output, or vice versa) | B |
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (CONNECTOR - ECM) |
![]() |
Disconnect the ED2 connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| ED2 male connector 10 - D56-94 (KNK1) | Always | Below 1 Ω |
| ED2 male connector 9 - D56-93 (EKNK) | Always | Below 1 Ω |
| ED2 male connector 4 - D56-117 (KNK2) | Always | Below 1 Ω |
| ED2 male connector 5 - D56-116 (EKN2) | Always | Below 1 Ω |
| ED2 male connector 10 or D56-94 (KNK1) - Body ground | Always | 10 kΩ or higher |
| ED2 male connector 9 or D56-93 (EKNK) - Body ground | Always | 10 kΩ or higher |
| ED2 male connector 4 or D56-117 (KNK2) - Body ground | Always | 10 kΩ or higher |
| ED2 male connector 5 or D56-116 (EKN2) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT ECM (VOLTAGE) |
![]() |
Disconnect the ED2 connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| ED2 male connector 10 - 9 | Ignition switch ON | 4.5 to 5.5 V |
| ED2 male connector 4 - 5 | Ignition switch ON | 4.5 to 5.5 V |
|
| ||||
| OK | ||
| ||
| 4.INSPECT KNOCK SENSOR |
![]() |
Disconnect the ED2 connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| ED2 female connector 10 - 9 | 20°C (68°F) | 120 to 280 kΩ |
| ED2 female connector 4 - 5 | 20°C (68°F) | 120 to 280 kΩ |
| Result | Proceed to |
| Outside standard range | A |
| Within standard range | B |
|
| ||||
| A | |
| 5.CHECK HARNESS AND CONNECTOR (CONNECTOR - KNOCK SENSOR) |
![]() |
Disconnect the ED2 connector.
Disconnect the knock sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| ED2 female connector 10 - E10-2 | Always | Below 1 Ω |
| ED2 female connector 9 - E10-1 | Always | Below 1 Ω |
| ED2 female connector 4 - E9-2 | Always | Below 1 Ω |
| ED2 female connector 5 - E9-1 | Always | Below 1 Ω |
| ED2 female connector 10 or E10-2 - Body ground | Always | 10 kΩ or higher |
| ED2 female connector 9 or E10-1 - Body ground | Always | 10 kΩ or higher |
| ED2 female connector 4 or E9-2 - Body ground | Always | 10 kΩ or higher |
| ED2 female connector 5 or E9-1 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||