AIRBAG SYSTEM > SRS Warning Light Remains ON |

| 1.CHECK CAN COMMUNICATION SYSTEM |
Check if a CAN communication DTC is output (Click here).
| Result | Proceed to |
| DTC is not output | A |
| DTCs are output | B |
|
| ||||
| A | |
| 2.CHECK BATTERY |
Measure the voltage of the battery.
| Tester Connection | Condition | Specified Condition |
| Battery | Always | 11 to 14 V |
|
| ||||
| OK | |
| 3.CHECK CONNECTORS |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor and combination meter.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF CENTER AIRBAG SENSOR) |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Operate all components of the electrical system (defogger, wipers, headlights, heater blower, etc.).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H56-21 (IG2) - H56-25 (E1) | Ignition switch ON | 11 to 14 V |
| H56-21 (IG2) - H56-26 (E2) | Ignition switch ON | 11 to 14 V |
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF COMBINATION METER) |
![]() |
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connector from the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H37-18 (B) - H37-40 (E1) | Always | 11 to 14 V |
| H37-20 (IG+) - H37-40 (E1) | Ignition switch ON | 11 to 14 V |
|
| ||||
| OK | |
| 6.CHECK SRS WARNING LIGHT |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the connector to the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Check the SRS warning light condition.
|
| ||||
| OK | ||
| ||