Home › Power Source / Network · NETWORKING › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > Open in CAN Main Wire

for Preparation Click here


DESCRIPTION

There may be an open circuit in the CAN main wire and/or the DLC3 branch wire when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 70 Ω or higher.

Symptom
Trouble Area
Resistance between terminals 6 (CANH) and 14 (CANL) of DLC3 is 70 Ω or higher.
  1. CAN main wire and connector
  2. No. 1 junction connector
  3. No. 2 junction connector
  4. No. 4 junction connector*
  5. ECM
  6. Combination meter assembly
  1. *: w/ Air Suspension System

WIRING DIAGRAM


C245664E02


INSPECTION PROCEDURE

HINT:
Operating the ignition switch, any other switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

1.PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).


NEXT


2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


3.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - DLC3)


    C242750E80
  1. Disconnect the H119 No. 1 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H19-6 (CANH) - H119-3 (CANH)
    Ignition switch off
    Below 1 Ω
    H19-14 (CANL) - H119-14 (CANL)
    Ignition switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 1 Junction Connector)
    *b
    Front view of DLC3



NG
REPAIR OR REPLACE CAN BRANCH WIRE CONNECTED TO DLC3 (CANH, CANL)
OK


4.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM)


    C242748E43
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H119-5 (CANH) - H119-16 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 1 Junction Connector)



NG
Go to step 6
OK


5.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - COMBINATION METER ASSEMBLY)


    C242748E44
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H119-2 (CANH) - H119-13 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 1 Junction Connector)
    Result 
    Result
    Proceed to
    OK
    A
    NG (w/o Air Suspension System)
    B
    NG (w/ Air Suspension System)
    C



B
Go to step 11

C
Go to step 13
A

REPLACE NO. 1 JUNCTION CONNECTOR 

6.CONNECT CONNECTOR
  1. Reconnect the H119 No. 1 junction connector.


NEXT


7.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - ECM)


    C242748E45
  1. Disconnect the H115 No. 2 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H115-3 (CANH) - H115-14 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 2 Junction Connector)



NG
Go to step 9
OK


8.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)


    C242748E46
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H115-4 (CANH) - H115-15 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 2 Junction Connector)



NG
REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)
OK

REPLACE NO. 2 JUNCTION CONNECTOR 

9.CONNECT CONNECTOR
  1. Reconnect the H115 No. 2 junction connector.


NEXT


10.CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 2 JUNCTION CONNECTOR)


    C234868E06
  1. Disconnect the A27 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A27-10 (CANH) - A27-11 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)
    Result 
    Result
    Proceed to
    OK (for 3UR-FBE)
    A
    OK (for 3UR-FE)
    B
    OK (for 1UR-FE)
    C
    NG
    D



B
REPLACE ECM (Click here)

C
REPLACE ECM (Click here)

D
REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO ECM (ECM - NO. 2 JUNCTION CONNECTOR)
A

REPLACE ECM (Click here)  

11.CONNECT CONNECTOR
  1. Reconnect the H119 No. 1 junction connector.


NEXT


12.CHECK FOR OPEN IN CAN BUS MAIN WIRE (COMBINATION METER ASSEMBLY - NO. 1 JUNCTION CONNECTOR)


    C242857E02
  1. Disconnect the H37 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H37-33 (CANH) - H37-34 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Combination Meter Assembly)



NG
REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO COMBINATION METER ASSEMBLY (COMBINATION METER ASSEMBLY - NO. 1 JUNCTION CONNECTOR)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

13.CONNECT CONNECTOR
  1. Reconnect the H119 No. 1 junction connector.


NEXT


14.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 4 JUNCTION CONNECTOR - COMBINATION METER ASSEMBLY)


    C242859E02
  1. Disconnect the O41 No. 4 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    O41-1 (CANH) - O41-7 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 4 Junction Connector)



NG
Go to step 16
OK


15.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 4 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)


    C242859E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    O41-2 (CANH) - O41-8 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to No. 4 Junction Connector)



NG
REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 4 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)
OK

REPLACE NO. 4 JUNCTION CONNECTOR 

16.CONNECT CONNECTOR
  1. Reconnect the O41 No. 4 junction connector.


NEXT


17.CHECK FOR OPEN IN CAN BUS MAIN WIRE (COMBINATION METER ASSEMBLY - NO. 4 JUNCTION CONNECTOR)


    C242857E02
  1. Disconnect the H37 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    H37-33 (CANH) - H37-34 (CANL)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Combination Meter Assembly)



NG
REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO COMBINATION METER ASSEMBLY (COMBINATION METER ASSEMBLY - NO. 4 JUNCTION CONNECTOR)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)