Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › AIRBAG SYSTEM

DTC    B181A/7A    Short in Passenger Side Airbag Variable Vent Hole Squib Circuit

DTC    B181B/7A    Open in Passenger Side Airbag Variable Vent Hole Squib Circuit

DTC    B181C/7A    Short to GND in Passenger Side Airbag Variable Vent Hole Squib Circuit

DTC    B181D/7A    Short to B+ in Passenger Side Airbag Variable Vent Hole Squib Circuit

for Preparation Click here


DESCRIPTION

The variable vent hole squib circuit consists of the center airbag sensor and front passenger airbag.
The circuit instructs the SRS to deploy when the deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the variable vent hole squib circuit.

DTC Code
Detection Condition
Trouble Area
B181A/7A
When one of the following conditions is met:
  1. The center airbag sensor receives a line short circuit signal 5 times in the variable vent hole squib circuit during primary check.
  2. Variable vent hole squib malfunction
  3. Center airbag sensor malfunction
  1. Instrument panel wire
  2. No. 2 instrument panel wire assembly
  3. Front passenger airbag assembly (Variable vent hole squib)
  4. Center airbag sensor assembly
B181B/7A
When one of the following conditions is met:
  1. The center airbag sensor receives an open circuit signal in the variable vent hole squib circuit for 2 seconds.
  2. Variable vent hole squib malfunction
  3. Center airbag sensor malfunction
  1. Instrument panel wire
  2. No. 2 instrument panel wire assembly
  3. Front passenger airbag assembly (Variable vent hole squib)
  4. Center airbag sensor assembly
B181C/7A
When one of the following conditions is met:
  1. The center airbag sensor receives a short circuit to ground signal in the variable vent hole squib circuit for 0.5 seconds.
  2. Variable vent hole squib malfunction
  3. Center airbag sensor malfunction
  1. Instrument panel wire
  2. No. 2 instrument panel wire assembly
  3. Front passenger airbag assembly (Variable vent hole squib)
  4. Center airbag sensor assembly
B181D/7A
When one of the following conditions is met:
  1. The center airbag sensor receives a short circuit to B+ signal in the variable vent hole squib circuit for 0.5 seconds.
  2. Variable vent hole squib malfunction
  3. Center airbag sensor malfunction
  1. Instrument panel wire
  2. No. 2 instrument panel wire assembly
  3. Front passenger airbag assembly (Variable vent hole squib)
  4. Center airbag sensor assembly

WIRING DIAGRAM


C146249E59


INSPECTION PROCEDURE

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (Click here).
  2. When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).

HINT:
  1. Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester (Click here).
  2. After selecting "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads (Click here).

1.CHECK FRONT PASSENGER AIRBAG (VARIABLE VENT HOLE SQUIB)
C158848E09
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect the connectors from the front passenger airbag.

  1. Connect the white wire side of SST (resistance: 2.1 Ω) to connector E (orange connector).

    CAUTION:
    Never connect the tester to the front passenger airbag (variable vent hole squib) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting SST.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B181A, B181B, B181C or B181D is not output.

    HINT:
    Codes other than DTC B181A, B181B, B181C and B181D may be output at this time, but they are not related to this check.



NG
Go to step 2
OK

REPLACE FRONT PASSENGER AIRBAG ASSEMBLY (Click here)  

2.CHECK CONNECTOR
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect SST from connector E.

  1. Check that the instrument panel wire connectors (on the front passenger airbag side) are not damaged.

    OK:
    The lock button is not disengaged, and the claw of the lock is not deformed or damaged.



NG
REPLACE NO. 2 INSTRUMENT PANEL WIRE ASSEMBLY
OK


3.CHECK VARIABLE VENT HOLE SQUIB CIRCUIT


    C158863E11
  1. Disconnect the connectors from the center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    z14-1 (P2+) - Body ground
    Ignition switch ON
    Below 1 V
    z14-2 (P2-) - Body ground

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    z14-1 (P2+) - z14-2 (P2-)
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    z14-1 (P2+) - z14-2 (P2-)
    Always
    1 MΩ or higher
    z14-1 (P2+) - Body ground
    z14-2 (P2-) - Body ground



NG
Go to step 5
OK


4.CHECK CENTER AIRBAG SENSOR
  1. Restore the released activation prevention mechanism of connector B to the original condition.



    C162203E05
  1. Connect the connectors to the front passenger airbag and center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B181A, B181B, B181C or B181D is not output.

    HINT:
    Codes other than DTC B181A, B181B, B181C and B181D may be output at this time, but they are not related to this check.

    Result 
    Result
    Proceed to
    OK
    A
    NG (w/ Cool Box)
    B
    NG (w/o Cool Box)
    C



B
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)

C
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)
A

USE SIMULATION METHOD TO CHECK (Click here)  

5.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR - NO. 2 INSTRUMENT PANEL WIRE ASSEMBLY)


    C209581E01
  1. Restore the released activation prevention mechanism of connector B to the original condition.

  1. Disconnect the instrument panel wire connector from the No. 2 instrument panel wire assembly.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    Hz2-1 - Body ground
    Ignition switch ON
    Below 1 V
    Hz2-2 - Body ground

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Hz2-1 - Hz2-2
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Hz2-1 - Hz2-2
    Always
    1 MΩ or higher
    Hz2-1 - Body ground
    Hz2-2 - Body ground



NG
REPLACE INSTRUMENT PANEL WIRE
OK

REPLACE NO. 2 INSTRUMENT PANEL WIRE ASSEMBLY