DTC C1747 Leveling Solenoid Valve Circuit Malfunction |
| DTC Code | Detection Condition | Trouble Area |
| C1747 | When either of the following is detected:
|
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (REAR LEVELING SOLENOID) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON, and turn the intelligent tester on.
Enter the following menus: Chassis / Air suspension / Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Rear Leveling Solenoid | Leveling solenoid valve | ON or OFF | Operation sound of solenoid (clicking sound) can be heard |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC Chart) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY (LEVELING SOLENOID VALVE) |
Turn the ignition switch off.
![]() |
Disconnect Q4 solenoid valve connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (E) - 3 (RH+) | 20°C (68°F) | 10 to 14 Ω |
Connect the battery positive (+) lead to terminal 3 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve makes an operating sound.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (LEVELING SOLENOID VALVE - ECU AND BODY GROUND) |
![]() |
Disconnect the O19 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q4-3 (RH+) - O19-3 (SLRR) | Always | Below 1 Ω |
| Q4-3 (RH+) or O19-3 (SLRR) - Body ground | Always | 10 kΩ or higher |
| Q4-2 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||