Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

DTC    U0233    Lost Communication with Blind Spot Monitor Master Module

for Preparation Click here


DESCRIPTION


DTC Code
DTC Detection Condition
Trouble Area
U0233
There is no communication from the blind spot monitor sensor RH.
  1. Power source or inside of blind spot monitor sensor RH
  2. Blind spot monitor sensor RH CAN branch wire or connector
  3. Blind spot monitor sensor RH
  1. For vehicles with an blind spot monitor system.

WIRING DIAGRAM


C242848E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

1.PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).


NEXT


2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and CAN branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


3.CHECK FOR OPEN IN CAN BUS WIRE (BLIND SPOT MONITOR SENSOR RH CAN BRANCH WIRE)


    C242756E03
  1. Disconnect the P25 blind spot monitor sensor RH connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    P25-8 (CA1P) - P25-4 (CA1N)
    Ignition switch off
    54 to 69 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Blind Spot Monitor Sensor RH)



NG
REPAIR OR REPLACE BLIND SPOT MONITOR SENSOR RH CAN BRANCH WIRE OR CONNECTOR (CA1P, CA1N)
OK


4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BATTERY AND BODY GROUND)


    C242756E04
  1. Connect the cable to the negative (-) battery terminal.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    P25-5 (BRB) - Body ground
    Ignition switch ON
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P25-1 (BRGD) - Body ground
    Always
    Below 1 Ω

Text in Illustration 
*a
Front view of wire harness connector
(to Blind Spot Monitor Sensor RH)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BLIND SPOT MONITOR SENSOR RH (Click here)