Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › SFI SYSTEM
RM27L0U _51 Engine / Hybrid System _049294 3UR-FE ENGINE CONTROL _0235547 SFI SYSTEM C

3UR-FE ENGINE CONTROL  SFI SYSTEM  P0441  Evaporative Emission Control System Incorrect Purge Flow  


DTC SUMMARY

DTC Code Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P0441 Purge VSV (Vacuum Switching Valve) stuck open Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open.
·

Purge VSV

·

Connector/wire harness (Purge VSV - ECM)

·

ECM

·

Canister pump module

·

Leakage from EVAP system


While ignition switch off 2 trip
Purge VSV stuck closed After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. Reference pressure measured at start and at end of check.
If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed.
·

Purge VSV

·

Connector/wire harness (Purge VSV - ECM)

·

ECM

·

Canister pump module

·

Leakage from EVAP system


While ignition switch off 2 trip
Purge flow While engine running, following conditions successively met:
·

Negative pressure not created in EVAP system when purge VSV turned ON (open)

·

EVAP system pressure change less than 0.4 kPa-g (3 mmHg-g) when vent valve turned ON (closed)

·

Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa-g (0.75 mmHg-g)


·

Purge VSV

·

Connector/wire harness (Purge VSV - ECM)

·

Leakage from EVAP line (Purge VSV - Intake manifold)

·

ECM


While engine running 2 trip

DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System (See page Engine / Hybrid System>3UR-FE ENGINE CONTROL>SFI SYSTEM>EVAP System).

CAUTION / NOTICE / HINT

MONITOR DESCRIPTION

The two monitors, Key-Off and Purge Flow, are used to detect malfunctions relating to DTC P0441. The Key-Off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours* after the ignition switch is turned off. The purge flow monitor runs while the engine is running.

1.

KEY-OFF MONITOR

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure measured and then monitoring result recorded by ECM. -

HINT:

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


A112612E64
1.115,0.51 1.219,0.927 false 1.625,2.188 2,2.396 false 2.458,1.146 2.823,1.083 false 1.813,1.583 2.792,1.375 true 2.417,1.656 2.802,1.635 false 2.583,2.063 2.854,2.063 false 1.219,3.313 1.219,3.438 false 1.271,4.49 1.552,4.51 false 2.313,3.188 1.844,3.948 true 5.083,0.958 5.083,1.083 false 5.667,1.583 6.302,1.292 true 5.292,2.188 5.417,2.146 false 5.76,3.948 6.323,3.615 true 5.188,4.49 5.438,4.5 false 5.094,3.302 5.094,3.438 false 1.594,1.083 1.688,0.677 false 0.646,2.167 1.448,1.948 false 5.01,1.719 4.719,2.344 true 0.104,0.104 3.542,0.292 3.438,0.188 10 false Operation A: Atmospheric Pressure Measurement 0.344,2.75 3.708,2.938 3.365,0.188 10 false Operation C: EVAP System Pressure Measurement 4.469,0.042 5.615,0.229 1.146,0.188 10 false Operation B, E: 4.479,0.333 7.01,0.521 2.531,0.188 10 false Reference Pressure Measurement 4.552,2.698 7,2.917 2.448,0.219 10 false Operation D: Purge VSV Monitor 0.052,0.417 1.208,0.625 1.156,0.208 10 false Purge VSV: OFF 1.729,0.563 2.26,0.74 0.531,0.177 10 false Canister 2.854,0.938 3.49,1.115 0.635,0.177 10 false Fuel Tank 2.854,1.271 4.292,1.448 1.438,0.177 10 false Vent Valve: OFF (vent) 2.854,1.573 4.542,1.792 1.688,0.219 10 false Canister Pump Module 2.917,1.979 3.823,2.156 0.906,0.177 10 false Canister Filter 0.042,1.938 0.646,2.5 0.604,0.563 10 false Canister Pressure Sensor 1.573,2.396 3.354,2.573 1.781,0.177 10 false Leak Detection Pump: OFF 1.073,3.458 1.417,3.635 0.344,0.177 10 false OFF 1.042,4.396 1.323,4.583 0.281,0.188 10 false ON 2.354,3.083 3.115,3.26 0.76,0.177 10 false ON (closed) 3.385,3.521 4.198,3.885 0.813,0.365 10 false Atmospheric Pressure 3.385,4.031 4.063,4.396 0.677,0.365 10 false Negative Pressure 4.927,1.104 5.25,1.281 0.323,0.177 10 false OFF 6.365,1.188 7.083,1.385 0.719,0.198 10 false OFF (vent) 5.021,2.094 5.281,2.271 0.26,0.177 10 false ON 4.104,2.375 6.354,2.563 2.25,0.188 10 false Reference Orifice (0.02 Inch) 5.01,3.458 5.281,3.646 0.271,0.188 10 false ON 4.906,4.396 5.156,4.573 0.25,0.177 10 false ON 6.344,3.563 7.146,3.771 0.802,0.208 10 false ON (closed)

1.

Purge VSV stuck open

In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second reference pressure x 0.2], the ECM interprets this as the purge VSV (Vacuum Switching Valve) being stuck open. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

U153011E02
3.969,3.333 3.688,3.667 false 4.458,2.271 4.677,2.552 false 0.979,3.281 1.125,3.542 false 6.125,3.24 5.896,2.958 false 0.042,0.042 3.135,0.271 3.094,0.229 12 false EVAP Pressure when Purge Stuck Open: 0.344,0.677 1.135,0.885 0.792,0.208 10 false Purge VSV 0.354,1.073 1.188,1.281 0.833,0.208 10 false Vent Valve 0.156,1.396 1.135,1.771 0.979,0.375 10 false Leak Detection Pump 1.635,4.438 1.833,4.656 0.198,0.219 10 false 60 3.667,2.083 4.875,2.292 1.208,0.208 10 false Malfunction 6.208,0.25 6.927,0.458 0.719,0.208 10 false ON: Open 6.208,0.833 7.042,1.052 0.833,0.219 10 false OFF: Closed 6.208,1.083 7.094,1.292 0.885,0.208 10 false ON: Closed 6.208,1.406 6.958,1.615 0.75,0.208 10 false OFF: Vent 0.094,2 1.188,2.208 1.094,0.208 10 false EVAP Pressure 0.219,2.302 1.073,2.521 0.854,0.219 10 false Positive 0.188,2.667 1.208,2.885 1.021,0.219 10 false Negative 0.042,3.052 1.052,3.438 1.01,0.385 10 false First Reference Pressure 0.448,4.125 1.188,4.333 0.74,0.208 10 false Sequence 0.146,4.448 1.104,4.656 0.958,0.208 10 false Time (Second) 4.01,3.198 4.49,3.406 0.479,0.208 10 false OK 3.917,1.635 4.396,1.844 0.479,0.208 10 false ON 3.917,1.135 4.396,1.344 0.479,0.208 10 false ON 5.094,0.594 5.573,0.802 0.479,0.208 10 false ON 5.115,4.188 5.323,4.396 0.208,0.208 10 false D 5.688,4.177 5.896,4.385 0.208,0.208 10 false E 3.865,4.177 4.073,4.385 0.208,0.208 10 false C 2.552,4.146 2.76,4.354 0.208,0.208 10 false B 1.646,4.177 1.854,4.385 0.208,0.208 10 false A 6.177,2.917 7.156,3.469 0.979,0.552 10 false [Second Reference Pressure] x 0.2 3.438,4.438 5.125,4.646 1.688,0.208 10 false Within 15 minutes 2.49,4.438 2.781,4.656 0.292,0.219 10 false 360 5.083,4.427 5.281,4.646 0.198,0.219 10 false 10 5.656,4.427 5.854,4.646 0.198,0.219 10 false 60

2.

Purge VSV stuck closed

In operation D, the canister pressure sensor measures the EVAP system pressure. The pressure measurement for the purge VSV monitor is begun when the purge VSV is turned ON (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa-g (2.25 mmHg-g) or more, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

U152951E02
4.823,2.208 5.156,2.677 false 0.99,3.146 1.125,3.417 false 4.646,2.792 5.281,3.677 false 0.042,0.021 3.688,0.427 3.646,0.406 12 true EVAP Pressure when Purge VSV Stuck Closed: 0.292,0.531 1.042,0.75 0.75,0.219 10 false Purge VSV 0.375,0.948 1.073,1.167 0.698,0.219 10 false Vent Valve 0.177,1.271 1.167,1.625 0.99,0.354 10 false Leak Detection Pump 0.083,1.844 1.188,2.052 1.104,0.208 10 false EVAP Pressure 0.146,2.125 0.844,2.333 0.698,0.208 10 false Positive 0.146,2.531 0.927,2.74 0.781,0.208 10 false Negative 0.042,2.938 1.052,3.323 1.01,0.385 10 false First Reference Pressure 0.417,3.99 1.146,4.219 0.729,0.229 10 false Sequence 0.156,4.302 1.135,4.51 0.979,0.208 10 false Time (Second) 1.563,4.302 1.792,4.521 0.229,0.219 10 false 60 2.458,4.302 2.76,4.5 0.302,0.198 10 false 360 3.875,2.667 4.844,2.885 0.969,0.219 10 false Malfunction 6.292,0.365 6.979,0.583 0.688,0.219 10 false ON: Open 6.292,0.708 7.125,0.927 0.833,0.219 10 false OFF: Closed 6.292,1.271 6.99,1.49 0.698,0.219 10 false OFF: Vent 6.292,0.927 7.063,1.146 0.771,0.219 10 false ON: Closed 4.573,1.99 4.917,2.198 0.344,0.208 10 false OK 3.833,1.542 4.229,1.75 0.396,0.208 10 false ON 3.813,1.031 4.208,1.24 0.396,0.208 10 false ON 5.063,0.49 5.458,0.698 0.396,0.208 10 false ON 1.615,4.063 1.792,4.271 0.177,0.208 10 false A 2.542,4.063 2.719,4.271 0.177,0.208 10 false B 3.865,4.052 4.042,4.26 0.177,0.208 10 false C 5.115,4.052 5.292,4.26 0.177,0.208 10 false D 5.688,4.052 5.865,4.26 0.177,0.208 10 false E 3.417,4.323 5.104,4.531 1.688,0.208 10 false Within 15 minutes 5.104,4.302 5.333,4.521 0.229,0.219 10 false 10 5.667,4.313 5.896,4.51 0.229,0.198 10 false 60


2.

PURGE FLOW MONITOR

A371077E06
0.083,0.042 3.469,0.271 3.385,0.229 10 false EVAP Pressure During Purge Flow Monitor: 2.01,0.698 2.813,0.875 0.802,0.177 10 false Purge VSV 2.042,1.031 2.792,1.208 0.75,0.177 10 false Vent Valve 1.729,1.396 2.823,1.583 1.094,0.188 10 false EVAP Pressure 3.208,1.74 3.521,1.938 0.313,0.198 10 false OK 4.135,2.115 4.448,2.313 0.313,0.198 10 false OK 3.573,0.583 3.99,0.802 0.417,0.219 10 true Open 3.583,0.948 4.417,1.177 0.833,0.229 10 true ON (Closed) 4.333,1.229 5.135,1.406 0.802,0.177 10 false Malfunction 4.427,1.552 6.031,1.781 1.604,0.229 10 false 0.1 kPa-g (0.75 mmHg-g) 4.417,1.927 6.021,2.156 1.604,0.229 10 false 0.4 kPa-g (3.0 mmHg-g) 2.875,2.375 3.698,2.583 0.823,0.208 10 false 1st Monitor 3.802,2.375 4.625,2.583 0.823,0.208 10 false 2nd Monitor

The purge flow monitor consists of two monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.


·

The 1st monitor

While the engine is running and the purge VSV is ON (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.

·

The 2nd monitor

The vent valve is turned ON (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.4 kPa-g (3 mmHg-g), the ECM interprets this as the purge VSV being stuck closed, and illuminates the MIL and sets DTC P0441 (2 trip detection logic).


Atmospheric pressure check:

In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

OBD II MONITOR SPECIFICATIONS

Key-off Monitor


Monitor Strategy
Required Sensors/Components Purge VSV and canister pump module
Frequency of Operation Once per driving cycle
Duration Within 20 minutes (varies with fuel in tank): Purge VSV stuck open/ close
Within 30 seconds: Purge Flow
MIL Operation 2 driving cycles
Sequence of Operation None

Typical Enabling Conditions
Monitor runs whenever following DTCs not stored None
EVAP key-off monitor runs when all of following conditions met -
Atmospheric pressure 70 to 111 kPa-a (525 to 833 mmHg-a)
Battery voltage 10.5 V or more
Vehicle speed Below 4 km/h (2.5 mph)
Ignition switch Off
Time after key off 5 or 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key off Conditions 1 and 2
1. Duration that vehicle driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

Typical Malfunction Thresholds
Purge VSV stuck open: -
EVAP pressure when vacuum introduction complete Reference pressure x 0.2 or higher

Purge VSV stuck closed: -
EVAP pressure change after purge VSV ON (open) Less than 0.3 kPa-g (2.25 mmHg-g)


OBD II MONITOR SPECIFICATIONS

Purge Flow Monitor


Monitor Strategy
Required Sensors/Components Purge VSV and canister pump module
Frequency of Operation Once per driving cycle
Duration Within 30 seconds
MIL Operation 2 driving cycles
Sequence of Operation None

Typical Enabling Conditions
Monitor runs whenever following DTCs not present None
Engine Running
ECT 4.4°C (40°F) or more
IAT 4.4°C (40°F) or more
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
EVAP system check Not operated by scan tool
Atmospheric pressure 70 to 111 kPa-a (525 to 833 mmHg-a)
Battery voltage 10 V or more
Purge duty cycle 8% or more

Typical Malfunction Thresholds
Both of following conditions met Conditions 1 and 2
1. EVAP pressure change when purge operation started Less than 0.1 kPa-g (0.75 mmHg-g)
2. EVAP pressure change during purge operation when vent valve closed Less than 0.4 kPa-g (3.0 mmHg-g)


MONITOR RESULT

CONFIRMATION DRIVING PATTERN

A199237E34
0.796,1.207 1.193,1.400 0.397,0.193 10 Idling 0.11,1.618 1.298,1.811 1.188,0.193 10 Ignition Switch ON 2.16,2.3 3.464,2.483 1.304,0.184 10 15 minutes or more 5.24,2.234 6.234,2.587 0.993,0.353 10 Approximately 24 minutes 1.786,1.73 2.007,1.960 0.221,0.230 10 [A] 2.655,1.076 2.852,1.274 0.198,0.198 10 [B] 3.39,2.904 3.624,3.093 0.235,0.188 10 [C] 4.901,2.954 5.113,3.165 0.211,0.211 10 [D] 6.42,2.932 6.613,3.125 0.193,0.193 10 [E] 1.459,0.101 2.893,0.266 1.434,0.165 10 ECT: 4.4°C or more 1.485,0.335 2.781,0.517 1.296,0.182 10 IAT: 4.4°C or more

1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on [A].

6.

Start the engine and wait 15 minutes or more [B].

7.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [C].

8.

Read the Pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



9.

Enter the following menus: Powertrain / Engine and ECT / Utility / All readiness.

10.

Input the DTC: P0441.

11.

Check the DTC judgment result.

Tester Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit



NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by Techstream. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



12.

Turn the ignition switch to ON and turn the Techstream on.

13.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).

14.

Turn the ignition switch off and wait for at least 30 seconds.

15.

Turn the ignition switch to ON and turn the Techstream on [D].

16.

Enter the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

17.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

18.

Input the DTC: P0441.

19.

Check the DTC judgment result [E].

Tester Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit



HINT:

If the judgment result shows ABNORMAL, the system has a malfunction.


20.

If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (See page Engine / Hybrid System>3UR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.




PROCEDURE

1.GO TO EVAP SYSTEM

NEXT

END