11209
1.REMOVE V-BANK COVER SUB-ASSEMBLY
17650
2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Disconnect the vacuum switching valve connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 2 - Body ground |
If the result is not as specified, replace the vacuum switching valve assembly.
Check the vacuum switching valve operation.
When applying a vacuum to port E, check that air is sucked into the filter.
If the result is not as specified, replace the vacuum switching valve assembly.
Apply voltage across the terminals.
When applying a vacuum to port F, check that air is sucked into port E.
If the result is not as specified, replace the vacuum switching valve assembly.
Connect the vacuum switching valve connector.
11209
3.INSTALL V-BANK COVER SUB-ASSEMBLY