Home › Drivetrain › AB60F AUTOMATIC TRANSMISSION / TRANSAXLE › TRANSMISSION WIRE
RM27L0U _52 Drivetrain _049310 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0235647 TRANSMISSION WIRE G

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  TRANSMISSION WIRE  INSPECTION  


PROCEDURE

Hide 82125J 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

a.
C159421E75
2.177,1.99 2.5,2.302 true 2,2 1.906,2.313 true 2.25,1.698 2.604,1.24 true 2.083,1.677 1.99,1.219 true 2.396,2.333 2.833,2.521 0.438,0.188 10 false OT+ 1.688,2.344 2.125,2.531 0.438,0.188 10 false OT2+ 0.083,0.094 2.667,0.458 2.583,0.365 10 false Component without harness connected: (No. 1 Transmission Wire) 2.656,1.115 3.094,1.302 0.438,0.188 10 false OT- 1.813,1.042 2.25,1.229 0.438,0.188 10 false OT2-

Measure the resistance according to the value(s) in the table below.

HINT:

If the resistance is out of the specified range of any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard Resistance:
Tester Connection ATF Temperature Specified Condition
1 (OT-) - 9 (OT+) 10°C (50°F) 5 to 8 kΩ
1 (OT-) - 9 (OT+) 25°C (77°F) 2.5 to 4.5 kΩ
1 (OT-) - 9 (OT+) 110°C (230°F) 0.22 to 0.28 kΩ
2 (OT2-) - 10 (OT2+) 10°C (50°F) 5 to 8 kΩ
2 (OT2-) - 10 (OT2+) 25°C (77°F) 2.5 to 4.5 kΩ
2 (OT2-) - 10 (OT2+) 110°C (230°F) 0.22 to 0.28 kΩ


If the result is not as specified, replace the transmission wire.