Home › Drivetrain › AB60E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27L0U _52 Drivetrain _049311 AB60E AUTOMATIC TRANSMISSION / TRANSAXLE _0235670 AUTOMATIC TRANSMISSION SYSTEM C

AB60E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2742  Transmission Fluid Temperature Sensor "B" Circuit Low Input  P2743  Transmission Fluid Temperature Sensor "B" Circuit High Input  


DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor is on the transmission, just in front of the oil cooler inlet pipeline.

If the ECM detects an abnormally high ATF temperature near this sensor, the ATF temperature warning light illuminates or a message is displayed in the combination meter.

HINT:
·

The temperature of ATF easily rises when towing, climbing hills, in traffic, etc.

·

If the ATF temperature sensor becomes short-circuited, the signal that indicates that the ATF temperature is 150°C (302°F) or higher is input into the ECM.



Vehicle conditions when the sensor is normal and when the sensor is short-circuited are indicated in the table below.

No. 2 ATF Temperature Sensor State Detection Condition Symptom Recovery Condition
Sensor is normal ATF temperature more than 150°C (302°F) ATF temperature warning light is illuminated or message is displayed in combination meter ATF temperature less than 135°C (275°F)*1
ATF temperature more than 130°C (266°F) Shift point too high ATF temperature less than 110°C (230°F)
When the conditions (a) and (b) are satisfied.
(a) ATF temperature more than 130°C (266°F)
(b) Engine coolant temperature more than 95°C (203°F)
Lock-up at 3rd gear*2 ATF temperature less than 110°C (230°F)*1 and engine coolant temperature more than 95°C (203°F)
Sensor is short-circuited Any conditions
·

ATF temperature warning light blinks or message is displayed in combination meter

·

Shift point too high


Symptoms still occur
Engine coolant temperature more than 95°C (203°F) Lock-up at 3rd gear*2 Symptoms still occur

HINT:

*1: When ATF temperature is in the normal range, it decreases to less than 135°C (275°F) within 5 minutes with the shift lever in P or N in an idling state.

*2: When ATF temperature is normal, transmission lock-up occurs in 5th or 6th gear with the shift lever in the D position or S6 range, in 5th gear with the shift lever in the S5 range, and 4th gear with the shift lever in the S4 range.


DTC Code DTC Detection Condition Trouble Area
P2742 No. 2 ATF temperature sensor resistance is less than 25 Ω (0.046 V) for 0.5 seconds or more. (1-trip detection logic)
·

Short in No. 2 ATF temperature sensor circuit

·

No. 1 transmission wire (No. 2 ATF temperature sensor)

·

ECM


P2743 No. 2 ATF temperature sensor resistance is higher than 156 kΩ (4.915 V) for 0.5 sec. or more and either condition is met (1-trip detection logic):
(A) 15 min. or more have elapsed after the engine start when the engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 sec. or more have elapsed after the engine start when the engine coolant temperature and intake air temperature are higher than -29.375°C (-20.875°F).
·

Open in No. 2 ATF temperature sensor circuit

·

No. 1 transmission wire (No. 2 ATF temperature sensor)

·

ECM



MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 25 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM stores a DTC and the ATF temperature warning light blinks or a message is displayed in the combination meter.

HINT:
·

*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

·

The ATF temperature can be checked on the Techstream display.



CAUTION / NOTICE / HINT

DATA LIST


HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the Techstream to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the Techstream on.


f.

Enter the following menus: Powertrain / Engine and ECT / Data List.


g.

According to the display on the Techstream, read the Data List.

Engine and ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/T Oil Temperature 2 No. 2 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·

After stall test: Approximately 80°C (176°F)

·

Equal to ambient temperature while engine is cold


If value is -40°C (-40°F) or 150°C (302°F), No. 2 ATF temperature sensor circuit is open or shorted

HINT:
·

When DTC P2742 is output and the Techstream output is 150°C (302°F) or higher, there is a short circuit.

·

When DTC P2743 is output and the Techstream output is -40°C (-40°F), there is an open circuit.

Measure the resistance between terminal THO2 and the body ground.



Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or higher Short circuit



PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR)
a.
C159421E43
1.523,2.631 1.957,2.776 0.434,0.145 10 OT2+ 0.058,0.046 2.640,0.413 2.582,0.367 10 Component without harness connected: (No. 1 Transmission Wire) 2.202,2.631 2.639,2.776 0.437,0.145 10 OT2- 2.018,2.024 1.76,2.592 false 2.086,1.804 2.391,2.592 false

Disconnect the D41 No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (OT2-) - 10 (OT2+) Always 25 Ω to 156 kΩ
2 (OT2-) - Body ground Always 10 kΩ or higher
10 (OT2+) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at one of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard Resistance:
ATF temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ




OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR)

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U153482E02
1.01,2.885 1.458,2.146 true 1.979,2.885 1.531,2.146 true 0.073,0.052 2.479,0.417 2.406,0.365 10 false Front view of wire harness connector: (to ECM) 1.573,1.042 1.948,1.271 0.375,0.229 10 false D56 1.625,2.896 2.396,3.094 0.771,0.198 10 false 99 (THO2) 0.5,2.896 1.219,3.094 0.719,0.198 10 false 98 (ETHA)

Disconnect the D56 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D56-99 (THO2) - D56-98 (ETHA) Always 25 Ω to 156 kΩ
D56-99 (THO2) - Body ground Always 10 kΩ or higher
D56-98 (ETHA) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR