Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM
RM27L0U _56 Audio / Visual / Telematics _049331 PARK ASSIST / MONITORING _0235792 BLIND SPOT MONITOR SYSTEM U

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  TERMINALS OF ECU  


CHECK BLIND SPOT MONITOR SENSOR RH


U154151E02
1.583,0.281 1.938,0.448 0.354,0.167 10 false P25

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
P25-1 (BRGD) - Body Ground W-B - Body ground Ground Always Below 1 V
P25-2 (BSTR) - P25-1 (BRGD) LG - W-B Turn signal switch signal Ignition switch ON, blind spot monitor main switch assembly (warning canceling switch assembly) on, turn signal switch in right turn position 11 to 14 V
P25-3 (BSSW) - P25-1 (BRGD) B - W-B Blind spot monitor main switch assembly (warning canceling switch assembly) power source signal Ignition switch ON, blind spot monitor main switch assembly (warning canceling switch assembly) on 11 to 14 V
Ignition switch ON, blind spot monitor main switch assembly (warning canceling switch assembly) off Below 1 V
P25-5 (BRB) - P25-1 (BRGD) BR - W-B IG power source signal Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
P25-6 (OMIR) - P25-1 (BRGD) B - W-B Blind spot monitor indicator power source signal RH Blind spot monitor indicator illuminated 8.5 to 14 V
Blind spot monitor indicator not illuminated Below 3 V


CHECK BLIND SPOT MONITOR SENSOR LH


U154152E02
1.594,0.302 1.927,0.469 0.333,0.167 10 false O46

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
O46-1 (BLGD) - Body Ground W-B - Body ground Ground Always Below 1 V
O46-2 (BSTL) - O46-1 (BLGD) G - W-B Turn signal switch signal Ignition switch ON, blind spot monitor main switch assembly (warning canceling switch assembly) on, turn signal switch in left turn position 11 to 14 V
O46-3 (LGND) - Body Ground W-B - Body ground Ground Always Below 1 V
O46-5 (BLB) - O46-1 (BLGD) BR - W-B IG power source signal Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
O46-6 (OMIL) - O46-1 (BLGD) B - W-B Blind spot monitor indicator power source signal LH Blind spot monitor indicator illuminated 8.5 to 14 V
Blind spot monitor indicator not illuminated Below 3 V